255
UF-9000
APR 2006
Ver. 3.0
DP-180/190
7 Installation
7.1. Set Up Precautions
Before you begin the installation, read these entire instructions. You must locate an appropriate site (firm
and leveled surface) for the installation. Reading this section assists you with the decision making process.
Machine performance and the copy quality is subject to and dependant on environmental conditions.
To maintain good performance, quality, and safe operation, observe the following precautions:
1. For safe operation and to avoid trouble, do not install the system under the following conditions:
• Extremely high or low temperature and humidity.
Ambient conditions
Temperature: 50 - 86
°
F (10 - 30
°
C)
Relative humidity: 30 - 80 %
• Sudden changes in temperature or humidity
• Exposed to direct sunlight
• Dusty environment
• Poorly ventilated location
• Exposed to chemical gases (such as ammonia gas)
• Exposed to strong vibration
• Exposed to direct air current (ex. Air conditioner vent)
2. The weight of the machine (options not included) is as follows:
UF-9000, DP-180/190: Approx. 48.5 lb (22 k
g
)
3. The maximum power consumption is 900 W for 120 VAC, or 1.0 kW for 220-240 VAC. Depending on
the product destination, the wall outlet must be rated for 120 VAC or 220-240 VAC accordingly. It must
also be protected for at least 15 Amps for 120 VAC, or 10 Amps for 220-240 VAC. If you are in doubt
about a power source, ensure that a qualified electrician checks the outlet. Do not connect any other
devices to the wall outlet designated for this machine. (Do not use an extension cord)
4. Make sure the outlet is properly grounded. (Do not ground to gas or water pipe)
5. The machine should be installed in a well-ventilated area to minimize the ozone density in the air.
6. This machine has ventilation openings on the side and rear, which must remain unobstructed for safe
operation. The machine should be located at least 3.94 inches (100 mm) from the wall. Obstructing the
ventilation openings could present a fire hazard.
Using the space requirements shown the following page, ensures that the machine has the ventilation
it requires and that you have the space needed for replacing the supplies.
Содержание DP-180
Страница 50: ...50 UF 9000 APR 2006 Ver 3 0 DP 180 190 21 Remove the LCD Module 127 ...
Страница 74: ...74 UF 9000 APR 2006 Ver 3 0 DP 180 190 3 3 Preventive Maintenance Points ...
Страница 126: ...126 UF 9000 APR 2006 Ver 3 0 DP 180 190 Sensor and Switch Location ...
Страница 196: ...196 UF 9000 APR 2006 Ver 3 0 DP 180 190 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 341: ...341 UF 9000 APR 2006 Ver 3 0 DP 180 190 memo ...
Страница 343: ...343 APR 2006 Ver 3 0 UF 9000 DP 180 190 memo ...
Страница 344: ...DZSD001829 13 88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 ...
Страница 359: ...Published in Japan ...
Страница 360: ...DZSD000965 16 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 ...
Страница 371: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next ...
Страница 375: ...Published in Japan ...