Preparing the Main Unit for the Programming Master Card
Important: DO NOT connect the USB Cable yet.
1. Turn the Power Switch on the left side of the machine to the OFF position. (During a Lightning
Storm, to prevent electrocution disconnect the Telephone Line Cable first before unplugging the AC
Power Cord.)
2. Insert/Remove the Flash Memory Card (4 MB or 8 MB) into/from the machine.
3. Turn the Power Switch on the Left Side of the machine to the ON position.
4. Press
“FUNCTION”
,
“ORIGINAL SIZE”
keys and then Key
“3”
on the keypad sequentially.
5. Perform the Update Program Card Mode F9-09
(Update Program Card)
.
The unit is now ready to accept the firmware code from the USB Port.
Now connect the USB Cable between the Unit and PC.
(Refer to the Local Firmware Update Tool OI on the CD)
Repeat the above steps if there are additional master firmware cards to be programmed.
B. Copying the Firmware from an Existing Machine using a Flash Memory Card (4 MB or 8 MB)
1. Turn the Power Switch on the left side of the machine to the OFF position. (During a Lightning
Storm, to prevent electrocution disconnect the Telephone Line Cable first before unplugging the AC
Power Cord.)
2. Install a Flash Memory Card (4 MB or 8 MB) into the machine.
3. Turn the Power Switch on the Left Side of the machine to the ON position.
4. Press
“FUNCTION”
,
“ORIGINAL SIZE”
keys and then Key
“3”
on the keypad sequentially.
5. Perform the Copy Service Mode F9-08
(Program Backup)
.
6. The firmware is copied into the Flash Memory Card.
7. After the backup is completed, press
"STOP"
first and then press
"FUNCTION"
+
"CLEAR"
keys
simultaneously to return to standby.
8. Turn the Power Switch on the left side of the machine to the OFF position.
9. Remove the Master Firmware Card that you just created from the machine.
10. Turn the Power Switch on the Left Side of the machine to the ON position.
11. Use this Master Firmware Card to update the firmware on other machines.
3.5.6.
Erasing the Master Firmware Card
1. Turn the Power Switch on the left side of the machine to the OFF position. (During a Lightning
Storm, to prevent electrocution disconnect the Telephone Line Cable first before unplugging the AC
Power Cord.)
2. Install the Master Firmware Card into the machine.
3. Turn the Power Switch on the Left Side of the machine to the ON position.
4. Press
“FUNCTION”
,
“ORIGINAL SIZE”
keys and then Key
“3”
on the keypad sequentially.
5. Perform the Service Mode F9-09
(Update Program Card)
.
6. After the Flash Memory Card is erased, machine prompts
“READY TO PROGRAM PRESS SET
TO START”
. Press
“STOP”
.
7. Press
"STOP"
first and then press
"FUNCTION"
+
"CLEAR"
keys simultaneously to return to
standby.
8. Turn the Power Switch on the left side of the machine to the OFF position.
9. Remove the blank Flash Memory Card from the machine.
10. Repeat from Step 2 above if you are erasing another Master Firmware Card.
Содержание DP-180
Страница 50: ...50 UF 9000 APR 2006 Ver 3 0 DP 180 190 21 Remove the LCD Module 127 ...
Страница 74: ...74 UF 9000 APR 2006 Ver 3 0 DP 180 190 3 3 Preventive Maintenance Points ...
Страница 126: ...126 UF 9000 APR 2006 Ver 3 0 DP 180 190 Sensor and Switch Location ...
Страница 196: ...196 UF 9000 APR 2006 Ver 3 0 DP 180 190 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 341: ...341 UF 9000 APR 2006 Ver 3 0 DP 180 190 memo ...
Страница 343: ...343 APR 2006 Ver 3 0 UF 9000 DP 180 190 memo ...
Страница 344: ...DZSD001829 13 88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 ...
Страница 359: ...Published in Japan ...
Страница 360: ...DZSD000965 16 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 ...
Страница 371: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next ...
Страница 375: ...Published in Japan ...