51
HDD READ VERIFY
Inspection
Measure of access time in READ VERIFY
MODE of HDD.
At start.
The [*] sign is added every approx. 10
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection (The
unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding 0)
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.)
$: [X] is displayed when seek time is
over 270msec., there is error or
transfer rate is NG.
Position at $ is space when excluding
those.
##: Number of data of over 100msec.
and less than 270msec.
When it is over 100, [99] is displayed.
When the number is less than 5, we
judge it normal.
Press [3] [2] in service mode.
* When cancelling the inspection
mode while executing, do "forced
power-off".
Method:
Press [POWER] key on the main
unit more than 4 seconds.
HDD Spin-up time
The accumulation value of the Spin-up time
of HDD is displayed.
Spin-up time of HDD is displayed.
(The unit of display is hour.)
Press [3] [3] in service mode.
Item
FL display
Key operation
Mode name
Description
(Remote control key)
Содержание DMR-UBS80EG