Section
4. Trunks and Lines
Connect the test set across the tip and ring of the trunk to be tested.
the test set in the “monitor” position, apply ground to the ring side of the
trunk.
If you hear dial tone, the polarity of the trunk is okay, and you can switch
the test set to the “talk” mode to test the voice path.
If you do not hear dial tone, ground the tip side of the trunk. If you
receive dial tone when grounding the tip side, polarity is reversed.
Interface
Guidelines
Read the following guidelines before beginning
installation. Installation
instructions begin on page 4-2 1.
Hardware Requirements
l
The
requires the following DBS hardware.
Table
Hardware requirements for single-cabinet systems
CPC-B 4.0 or
Trunk Card
MDF Card
Sync Unit
Higher
(VB-43421)
(VB-4356 1)
(VB-43562)
(VB-43563)
1
1
1
1
(See Note 1.)
(See Notes 2 and 3.)
Notes:
1. Version
1.3 or higher of
Bus Processor Unit (BPU) chip is required for
2. An MFR card is required for
if DTMF signaling is used. If
is provided through
DP signaling, an MFR card is not
3. SCC-B with ROM 1.3 or higher is required if the central
does not provide
dial
DBS-70-300
DBS Manual Issued 8/t/95
4-11
Содержание DBS 96
Страница 10: ...List of Tables Section 300 installation X DBS Manual Issued 8 l 95 DBS 70 300 ...
Страница 13: ...1 2 DES Manual Revised 4 3 96 DES 70 300 ...
Страница 19: ...DES Manual Issued 8 l 95 DES 70 300 ...
Страница 28: ...3 2 DBS Manual Issued 8 l 95 DES 70 300 ...
Страница 47: ...4 2 DBS Manual Issued 8 l 95 DBS 70 300 ...
Страница 91: ...5 2 DBS Manual Issued 8 l 95 DBS 70 300 ...
Страница 127: ...6 2 DBS Manual Issued 8 l 95 DBS 70 300 ...
Страница 139: ...7 2 DES Manual Issued 8 l 95 DBS 70 300 ...