Chapter 3. Cabinet Installation
System Initialization
1. Confirm that the DBS power switch is
OFF.
2. Plug the power cord into a dedicated 120V 15 amp AC wall outlet.
Note: A surge protector should be installed on the power cord.
3. Set SW1 on the CPC card to RAMCLR (RAM Clear).
‘igure 3-17. CPC memory clear switch
4. Turn the power switch on.
As the system loads, the bottom LED lamp on the CPC card will flash.
.
5. Once the bottom LED lamp on the CPC card stops flashing, set SW on
the CPC to
DES-70-300
DBS Manual Issued
3-l 7