background image

4

 Safety precautions

To prevent personal injury, injury to others or property 
damage, please comply with the following: 
Incorrect operation due to failure to follow instructions 
below may cause harm or damage, the seriousness of 
which is classifi ed as below:
This appliances is not intended for accessibility by the 
general public.

WARNING

This sign warns of death 
or serious injury.

CAUTION

This sign warns of injury 
or damage to property.

The instructions to be followed are classifi ed by the 
following symbols:

This symbol denotes an action that 
is PROHIBITED.

These symbols denote actions 
COMPULSORY.

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they 
have been given supervision or instruction 
concerning use of the appliance by a person 
responsible for their safety. Children should be 
supervised to ensure that they do not play with 
the appliance.

Please consult authorised dealer or specialist 
to clean the internal parts, repair, install, 
remove and reinstall the unit. Improper 
installation and handling will cause leakage, 
electric shock or fi re.

Confi rm with authorised dealer or specialist on 
usage of any specifi ed refrigerant type. Using 
refrigerant type other than the specifi ed may 
cause product damage, burst and injury etc.

Do not use means to accelerate the defrosting 
process or to clean, other than those 
recommended by manufacturer.
Any unfi t method or using incompatible material 
may cause product damage, burst and serious 
injury.

Do not install the unit in a potentially explosive 
or fl ammable atmosphere.
Failure to do so could result in fi re.
Do not insert your fi ngers or other 
objects into the air conditioner indoor or 
outdoor unit, rotating parts may cause 
injury.

Do not touch the outdoor unit during lightning, it 
may cause electric shock.

Do not expose yourself directly to cold air for a 
long period to avoid excess cooling.

Do not sit or step on the unit, you may 
fall down accidentally.

Remote control

Do not allow infants and small children to play 
with the remote control to prevent them from 
accidentally swallowing the batteries.

Power supply

Do not use a modifi ed cord, 
joint cord, extension cord or 
unspecifi ed cord to prevent 
overheating and fi re.

  

To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other 

equipment.

• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or 

pulling out the power plug.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air inlet

Air inlet

Air outlet

Air outlet

Air outlet

Air outlet

Содержание CS-Z20VKR

Страница 1: ...The included Installation Instructions should be kept and read by the installer before installation Remote control is packaged in the indoor unit and removed by the installer before installation Model No Indoor Unit Outdoor Unit CS Z20VKR CS Z25VKR CS Z35VKR CS Z42VKR CS Z50VKR CS Z60VKR CS Z71VKR CS Z80VKR CU Z20VKR CU Z25VKR CU Z35VKR CU Z42VKR CU Z50VKR CU Z60VKR CU Z71VKR CU Z80VKR ACXF55 2238...

Страница 2: ...e indoor unit Quick Guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm ON OFF SET CANCEL FAN SPEED MODE AIR SWING TEMP A B ...

Страница 3: ...er from the actual unit They are subject to change without notice for future improvement B Basic operation 1 Press MODE to select the desired mode AUTO HEAT COOL FAN i AUTO X DRY 2 Press OFF ON to start stop the operation POWER Please note that the indication is on display to start the unit 3 Select the desired temperature TEMP Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press and hold for app...

Страница 4: ...age of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean other than those recommended by manufacturer Any unfit method or using incompatible material may cause product damage burst and serious injury Do not install the unit in a potentially explosive or flamm...

Страница 5: ...s plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid injury etc Do not touch the sharp aluminium fin sharp parts may cause injury Do not switch ON the indoor unit when waxing the floor After waxing aerate the room properly befo...

Страница 6: ...al the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by the manufacturer Any personnel conducting an operation servicing or maintenance on a system or associated parts of the equipment should be trained and ce...

Страница 7: ...llow to the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a trained and certified service personnel who is employed by the person user or party responsible Ensure the actual refrigerant charge is in accordance with the room size wit...

Страница 8: ...ternally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations u...

Страница 9: ... supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation Particular attention shall be paid to the following to ensu...

Страница 10: ...ommenced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refrigerant cylinders all personal protective equipment is available and being used correctly the recovery process is supervised at all times by a competent person recovery equipment and cylin...

Страница 11: ...nsure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Recovery cylinders are evacuated and if p...

Страница 12: ...cally after 4 hours QUIET To enjoy quiet operation This operation reduces airflow noise To improve humidity and moisture level This operation reduces air dryness and provides you with a comfortable living environment during COOL mode only When vertical airflow direction is set to AUTO it stops at lower position to avoid cold air contact However you can adjust the flap direction manually MILD DRY T...

Страница 13: ...of ON and OFF timers are available to turn ON or OFF the unit at different preset times How to use The unit controls set temperature according to room temperature to accelerate room cooling After max 4 hours the set temperature is shifted according to activity detection Fan speed is fixed at AUTO fan speed selection is prohibited During unit is off press will turn on the unit with i AUTO X mode i ...

Страница 14: ...and shift to the upper position after reaches set temperature and the vertical flap swing according to activity detection If manual is set the horizontal flap and vertical flap are fixed at the predetermined position In HEAT mode If AUTO is set the horizontal flap is fixed at the predetermined position The vertical flap swings left right after the temperature rises Auto restart control If power is...

Страница 15: ...Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Insert into the unit Aluminium fin Front panel Air filters Indoor unit Wipe the unit gently with a soft dry cloth Coils and fans should be clean for at least every 6 months by an authorised dealer Human activity sensor Do not hit or violently press or poke it wit...

Страница 16: ...pansion contraction of the unit Water flowing sound during operation Refrigerant flow inside the unit Mist emerges from indoor unit Condensation effect due to cooling process Outdoor unit emits water steam Condensation or evaporation occurs on pipes Louder noise at outdoor unit during early operation of i AUTO X The compressor and fan rotate at higher speed to boost cooling performance during init...

Страница 17: ...t vents Use Auto OFF ON button to select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units are not going to be used for a long period of time Activate HEAT mode for 2 3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth Turn...

Страница 18: ...ming pool sensor H 32 Outdoor heat exchanger temperature sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code Diagnostic display ...

Страница 19: ...cal symbol In this case it complies with the requirement set by the Directive for the chemical involved Information WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows type of fl...

Страница 20: ...Printed in Malaysia ACXF55 22380 FA0319 0 Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2019 ...