37
12.9. Horizontal Airflow Direction Control
• The horizontal airflow direction louvers can be adjusted manually by hand.
12.10. Timer Control
12.10.1. ON Timer
• When ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that the room will
reach nearly to the set temperature by the set time.
• For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time.
• For Heating operation, the operation will start 30 minutes before the set time.
• For Automatic operation, the indoor fan will operate at SLo speed for 25 seconds, 30 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
12.10.2. OFF Timer
• When OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
12.11. Random Auto Restart Control
• If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
• It will start with previous operation mode and airflow direction.
• If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
• This Random Auto Restart Control is not available when Timer is set.
12.12. Remote Control Signal Receiving Sound
• Long beep sound will be heard when:-
- Stopping the air conditioner using OFF/ON operation button.
• Short beep sound will be heard for other settings.
Содержание CS-YW9GKE
Страница 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS YW9GK CS YW12GK...
Страница 11: ...11 5 2 Outdoor Unit 5 2 1 CU YW9GK CU YW12GK...
Страница 12: ...12 6 Refrigeration Cycle Diagram...
Страница 13: ...13 7 Block Diagram...
Страница 15: ...15 9 Electronic Circuit Diagram...
Страница 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit Main Printed Circuit Board...
Страница 17: ...17 10 2 Indoor Unit Power Printed Circuit Board...
Страница 18: ...18 10 3 Indicator TOP VIEW BOTTOM VIEW...
Страница 21: ...21 3 For the embedded piping This can be used for left rear piping and left bottom piping also...
Страница 33: ...33 Normal Deicing Time Diagram Overload Deicing Time Diagram...
Страница 43: ...43...
Страница 44: ...44 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures...
Страница 45: ...45...
Страница 46: ...46 16 Technical Data 16 1 Thermostat Characteristics Cooling Soft Dry Heating...
Страница 48: ...48 16 3 Operation Characteristics 16 3 1 CS YW9GK CU YW9GK...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52 16 3 2 CS YW12GK CU YW12GK...
Страница 53: ...53...
Страница 54: ...54...
Страница 55: ...55...