SELECT THE BEST LOCATION
INDOOR UNIT
There should not be any heat source or steam near the
unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A
place
where
noise
prevention
is
taken
into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
Recommended installation height for indoor unit shall be
at least 2.5 m.
OUTDOOR UNIT
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could
be
affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
Do not place any obstacles which may cause a short
circuit of the discharged air.
Indoor/Outdoor Unit Installation Diagram
- 29 -
Attachedaccessories.
Model
CS/CU-XA9DKD
CS/CU-XA12DKD
Piping size
Max. Piping
Length
(m)
7
7
Max.
Elevation
(m)
5
5
Gas
3/8"
1/2"
Liquid
1/4"
1/4"
About 1.1 m
Piping direction
Attention not to
bend up drain hose
Length of power supply cord
Right
Right Bottom
Right Rear
Left
Rear
Left Bottom
Left
(Front side)
About 1.8 m
<
<
<
<
The indoor unit will actually face a different way.
This illustration is for explanation purposes only.
Installation plate
1
Sleeve ( )
Bushing Sleeve ( )
Putty (Gum type sealer) ( )
Vinyl tape (Wide) ( )
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Saddle ( )
Type designation 245 IEC 57
or heavier cord
Additional drain hose ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn t break.
Installation parts you
should purchase ( )
Gas side piping (
(
) 3/8"
Liquid side piping (
) 1/4"
10
cm
or
mor
e
Connecting cable ( )
Insulation of piping connections
Carry out insulation
after checking for
gas leaks and
secure with vinyl
tape.
Vinyl tape
100
cm
or mor
e
30
cm
or more
10 cm
or more
XA9DKD,
Gas side piping
) 1/2"
XA12DKD.
Oxygen tube 7
Cap (1)
Cap (2)
5 cm
or more
5c
m
or
more
No.
Accessories par Q
ty
. N
o
Accessories par Qty
.
1
2
3
4
Installation plate
Installation plate fixing
scre
w
Remote control
Battery
1
5
1
2
1
6
7
1
5
1
8
1
Drain elbow
9
1
Connecting Wire
(Connector)
Oxygen Tube
Insulating sleeve
Insulating material
(6-C OR E W IR E /1.5 mm
2
+2
CORE WIRE/0.50mm
2
)
CS-XA9DKD/ CU-XA9DKD/ CS-XA12DKD/ CU-XA12DKD