5
1. Cooling capacities are based on indoor temperature of 27
q
C D.B. (80.6
q
F D.B.), 19.0
q
C W.B. (66.2
q
F W.B.) and outdoor air
temperature of 35
q
C D.B. (95
q
F D.B.), 24
q
C W.B. (75.2
q
F W.B.)
2. Heating capacities are based on indoor temperature of 20
q
C D.B. (68
q
F D.B.) and outdoor air temperature of 7
q
C D.B. (44.6
q
F
D.B.), 6
q
C W.B. (42.8
q
F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASG20K1 or ASG32K1
PP
Motor Type
Transistor (8-pole)
DC (8-pole)
Input Power
W
30
—
Output Power
W
30
40
Fan Speed
Lo (Cool/Heat)
rpm
1100 / 1270
—
Me (Cool/Heat)
rpm
1320 / 1450
—
Hi (Cool/Heat)
rpm
1570 / 1630
870 / 850
SHi (Cool/Heat)
rpm
1610 / 1630
—
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2.1 x 11.4 x 23
2 x 24 x 17
Size (W x H x L)
mm
640 x 304 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
—
Type
One-Touch
—
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 1.32k (160 ~ 1.6k)
Heating; 1.55k (160 ~ 2.08k)
Starting Current
A
7.1
Running Current
A
Cooling; 6.1
Heating; 7.1
Maximum current
A
9.5
Power Factor
%
Cooling; 94
Heating; 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.0mm)
Length
m (ft)
1.5 (5)
Thermostat
Electrical
Protection Device
—
Annual Consumption
kWh
660
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Содержание CS-TE15HKE
Страница 8: ...8 5 Dimensions 5 1 Indoor Unit...
Страница 9: ...9 5 2 Outdoor Unit...
Страница 10: ...10 6 Refrigeration Cycle Diagram...
Страница 11: ...11 7 Block Diagram...
Страница 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit...
Страница 13: ...13 8 2 Outdoor Unit...
Страница 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Страница 15: ...15 9 2 Outdoor Unit...
Страница 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Printed Circuit Board...
Страница 17: ...17 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board...
Страница 20: ...20 3 For the embedded piping This can be used for left rear piping and left bottom piping also...
Страница 43: ...43 16 1 2 Removal of Electronic Controller...
Страница 44: ...44 16 1 3 Removal of Control Board...
Страница 45: ...45 16 1 4 Removal of Fan Motor and Cross Flow Fan...
Страница 46: ...46...
Страница 48: ...48 17 Technical Data 17 1 Operation Characteristics...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...