 Safety precautions

WARNING

Precaution for appliance 

fi

 lled 

with R32

Pay careful attention to the following 

points when operating the appliances 

and dealing with different refrigerants.

The appliance shall be installed, 

and/or operated in a room with 

fl

 oor area larger than Amin (m²) 

and keep away from ignition 

sources, such as heat/sparks/

open 

fl

 ame or hazardous areas 

such as gas appliances, gas 

cooking, reticulated gas supply 

systems or electric cooking 

appliances, etc. (Refer to Table 

A of Installation instructions table 

for Amin (m²))
Be aware that refrigerant may 

not contain an odour, highly 

recommended to ensure suitable 

fl

 ammable refrigerant gas 

detectors are present, operating 

and able to warn of a leak.

Since the working pressure is 

higher than that of refrigerant 

R22 models, some of the piping 

and installation and service tools 

are special.

Especially, when replacing a 

refrigerant R22 model with a new 

refrigerant R32 model, always 

replace the conventional piping 

and 

fl

 are nuts with the R32 and 

R410A piping and 

fl

 are nuts on 

the outdoor unit side.

The R32 

fl

 are nut and pipe on 

the outdoor unit side can also be 

used for a R410A model.
Models that use refrigerant R32 

and R410A have a different 

charging port thread diameter to 

prevent erroneous charging with 

refrigerant R22 and for safety.

Therefore, check beforehand. 

[The charging port thread 

diameter for R32 and R410A is 

12.7 mm (1/2 inch).]
Be extra careful so that foreign 

matter (oil, water, etc.) does not 

enter the piping.

Also, when storing the piping, 

securely seal the opening by 

pinching, taping, etc. (Handling 

of R32 is similar to R410A.)
This appliance shall be stored in 

a well ventilated area.
This appliance shall be stored 

in a room without continuously 

operating open 

fl

 ames and 

ignition sources.
This appliance shall be stored 

so as to prevent mechanical 

damage from occurring.
Do not use means to accelerate 

the defrosting process or 

to clean, other than those 

recommended by manufacturer. 

Any un

fi

 t method or using 

incompatible material may cause 

product damage, burst and 

serious injury.

This equipment must be earthed 

to prevent electrical shock or 

fi

 re.

Prevent electric shock by 

switching off the power supply 

and unplug:

 

-Before cleaning or servicing,

 

-When extended non-use, or

 

-During abnormally strong 

lightning activity.

ACXF55-11360_SM0717-0_EN.indd   6

ACXF55-11360_SM0717-0_EN.indd   6

13/6/2017   11:54:30 AM

13/6/2017   11:54:30 AM

Содержание CS-RZ25TKR

Страница 1: ...ns thoroughly and keep them for future reference The included Installation Instructions should be kept and read by the installer before installation Remote control is packaged in the indoor unit and removed by the installer before installation Model No Indoor Unit Outdoor Unit CS RZ25TKR CS RZ35TKR CU RZ25TKR CU RZ35TKR ECONOMY i AUTO X ACXF55 11360 ...

Страница 2: ...g the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm FAN SPEED AIR SWING ECONOMY ON OFF SET CANCEL TIMER TEMP OFF ON MODE FAN SPEED AIR SWING ECONOMY ON OFF CANCEL TIMER A B ...

Страница 3: ...6 F Press and hold for approximately 10 seconds to switch the temperature indication in C or F Thank you for purchasing Panasonic Air Conditioner WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition CAUTION This symbol shows type of flammable refrigerant contained in the ...

Страница 4: ... been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance The appliance shall be installed and operated in a room with floor area larger than 2 06m and keep away from ignition sources such as heat sparks open flame or hazardous areas such as gas appliances gas cook...

Страница 5: ... to prevent overheating and fire To prevent overheating fire or electric shock Do not share the same power outlet with other equipment Do not operate with wet hands Do not over bend the power supply cord Do not operate or stop the unit by inserting or pulling out the power plug If the supply cord is damaged it must be replaced by the manufacturer service agent or similarly qualified persons in ord...

Страница 6: ...tdoor unit side The R32 flare nut and pipe on the outdoor unit side can also be used for a R410A model Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent erroneous charging with refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R32 and R410A is 12 7 mm 1 2 inch Be extra careful so that foreign matter oil...

Страница 7: ... Water may enter the unit and degrade the insulation This may cause an electric shock Do not open window or door for long time during operation it may lead to inefficient power usage and uncomfortable temperature changes Prevent water leakage by ensuring drainage pipe is Connected properly Kept clear of gutters and containers or Not immersed in water After a long period of use or use with any comb...

Страница 8: ...erature up to 3 C automatically Brightness of all indicators will be dimmed ECONOMY The unit controls set temperature according to room temperature to accelerate room cooling After max 4 hours the set temperature follows the last set temperature setting Fan speed is fixed at AUTO fan speed selection is prohibited During unit is off press will turn on the unit with i AUTO X mode i AUTO X mode can b...

Страница 9: ...cancelled manually or due to power failure you can restore the timer again by pressing or to select respective or then press The nearest timer setting will be displayed and will activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are available to turn ON or OFF the ...

Страница 10: ... mode If AUTO is set the flaps swings up down automatically In i AUTO X mode If AUTO is set the horizontal flap is fixed at the lower position and shift to the upper position after reaches set temperature If manual is set the horizontal flap are fixed at the predetermined position In HEAT mode If AUTO is set the horizontal flap is fixed at the predetermined position Auto restart control If power i...

Страница 11: ... Replace any damaged filters Remove air filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under the shade away from fire or direct sunlight Replace the filter every 10 years or replace any damaged filter Part no CZ SA22P Indoor ...

Страница 12: ...ion of the unit Water flowing sound during operation Refrigerant flow inside the unit Mist emerges from indoor unit Condensation effect due to cooling process Outdoor unit emits water steam Condensation or evaporation occurs on pipes Louder noise at outdoor unit during early operation of i AUTO X The compressor and fan rotate at higher speed to boost cooling performance during initial operation Di...

Страница 13: ... inlet and outlet vents Use Auto OFF ON button to select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units are not going to be used for a long period of time Activate HEAT mode for 2 3 hours to remove moisture left in the internal parts thoroughly to prevent m...

Страница 14: ...31 Abnormal swimming pool sensor H 32 Outdoor heat exchanger temperature sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code Dia...

Страница 15: ...e symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Information ...

Страница 16: ...Printed in Malaysia ACXF55 11360 SM0717 0 Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2017 ...

Отзывы: