Panasonic CS-RZ25TKR Скачать руководство пользователя страница 5

5

English

Safety precautions

Do not use means to accelerate 

the defrosting process or 

to clean, other than those 

recommended by manufacturer. 

Any un

fi

 t method or using 

incompatible material may cause 

product damage, burst and 

serious injury.
Do not pierce or burn as the 

appliance is pressurized. Do not 

expose the appliance to heat,

fl

 ame, sparks, or other sources 

of ignition. Else it may explode 

and cause injury or death.
Do not install the unit in 

a potentially explosive or 

fl

 ammable atmosphere.

Failure to do so could result in 

fi

 re.

Do not insert your 

fi

 ngers 

or other objects into the 

air conditioner indoor or 

outdoor unit, rotating parts 

may cause injury.
Do not touch the outdoor unit 

during lightning, it may cause 

electric shock.
Do not expose yourself directly 

to cold air for a long period to 

avoid excess cooling.
Do not sit or step on the 

unit, you may fall down 

accidentally.

Remote control

Do not allow infants and small 

children to play with the remote 

control to prevent them from 

accidentally swallowing the 

batteries.

Power supply

Do not use a 

modi

fi

 ed cord, joint 

cord, extension cord 

or unspeci

fi

 ed cord to 

prevent overheating 

and 

fi

 re.

  

To prevent overheating, 

fi

 re or 

electric shock:

• Do not share the same power 

outlet with other equipment.

• Do not operate with wet hands.

• Do not over bend the power 

supply cord.

• Do not operate or stop the unit 

by inserting or pulling out the 

power plug.

If the supply cord is damaged, 

it must be replaced by the 

manufacturer, service agent or 

similarly quali

fi

 ed persons in 

order to avoid a hazard.
It is strongly recommended to 

be installed with Earth Leakage 

Circuit Breaker (ELCB) or 

Residual Current Device (RCD) 

to prevent electric shock or 

fi

 re.

To prevent overheating, 

fi

 re or 

electric shock:

• Insert the power plug properly.

• Dust on the power plug should 

be periodically wiped with a dry 

cloth.

Stop using the product if any 

abnormality/failure occurs and 

disconnect the power plug or 

turn off the power switch and 

breaker.

(Risk of smoke/

fi

 re/electric 

shock)

Examples of abnormality/failure

• The ELCB trips frequently.

• Burning smell is observed.

• Abnormal noise or vibration of 

the unit is observed.

• Water leaks from the indoor unit.

• Power cord or plug becomes 

abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running 

immediately even if it is 

switched on for operation.

• The fan does not stop even if 

the operation is stopped.

Contact your local dealer 

immediately for maintenance/

repair.

ACXF55-11360_SM0717-0_EN.indd   5

ACXF55-11360_SM0717-0_EN.indd   5

13/6/2017   11:54:30 AM

13/6/2017   11:54:30 AM

Содержание CS-RZ25TKR

Страница 1: ...ns thoroughly and keep them for future reference The included Installation Instructions should be kept and read by the installer before installation Remote control is packaged in the indoor unit and removed by the installer before installation Model No Indoor Unit Outdoor Unit CS RZ25TKR CS RZ35TKR CU RZ25TKR CU RZ35TKR ECONOMY i AUTO X ACXF55 11360 ...

Страница 2: ...g the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm FAN SPEED AIR SWING ECONOMY ON OFF SET CANCEL TIMER TEMP OFF ON MODE FAN SPEED AIR SWING ECONOMY ON OFF CANCEL TIMER A B ...

Страница 3: ...6 F Press and hold for approximately 10 seconds to switch the temperature indication in C or F Thank you for purchasing Panasonic Air Conditioner WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition CAUTION This symbol shows type of flammable refrigerant contained in the ...

Страница 4: ... been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance The appliance shall be installed and operated in a room with floor area larger than 2 06m and keep away from ignition sources such as heat sparks open flame or hazardous areas such as gas appliances gas cook...

Страница 5: ... to prevent overheating and fire To prevent overheating fire or electric shock Do not share the same power outlet with other equipment Do not operate with wet hands Do not over bend the power supply cord Do not operate or stop the unit by inserting or pulling out the power plug If the supply cord is damaged it must be replaced by the manufacturer service agent or similarly qualified persons in ord...

Страница 6: ...tdoor unit side The R32 flare nut and pipe on the outdoor unit side can also be used for a R410A model Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent erroneous charging with refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R32 and R410A is 12 7 mm 1 2 inch Be extra careful so that foreign matter oil...

Страница 7: ... Water may enter the unit and degrade the insulation This may cause an electric shock Do not open window or door for long time during operation it may lead to inefficient power usage and uncomfortable temperature changes Prevent water leakage by ensuring drainage pipe is Connected properly Kept clear of gutters and containers or Not immersed in water After a long period of use or use with any comb...

Страница 8: ...erature up to 3 C automatically Brightness of all indicators will be dimmed ECONOMY The unit controls set temperature according to room temperature to accelerate room cooling After max 4 hours the set temperature follows the last set temperature setting Fan speed is fixed at AUTO fan speed selection is prohibited During unit is off press will turn on the unit with i AUTO X mode i AUTO X mode can b...

Страница 9: ...cancelled manually or due to power failure you can restore the timer again by pressing or to select respective or then press The nearest timer setting will be displayed and will activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are available to turn ON or OFF the ...

Страница 10: ... mode If AUTO is set the flaps swings up down automatically In i AUTO X mode If AUTO is set the horizontal flap is fixed at the lower position and shift to the upper position after reaches set temperature If manual is set the horizontal flap are fixed at the predetermined position In HEAT mode If AUTO is set the horizontal flap is fixed at the predetermined position Auto restart control If power i...

Страница 11: ... Replace any damaged filters Remove air filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under the shade away from fire or direct sunlight Replace the filter every 10 years or replace any damaged filter Part no CZ SA22P Indoor ...

Страница 12: ...ion of the unit Water flowing sound during operation Refrigerant flow inside the unit Mist emerges from indoor unit Condensation effect due to cooling process Outdoor unit emits water steam Condensation or evaporation occurs on pipes Louder noise at outdoor unit during early operation of i AUTO X The compressor and fan rotate at higher speed to boost cooling performance during initial operation Di...

Страница 13: ... inlet and outlet vents Use Auto OFF ON button to select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units are not going to be used for a long period of time Activate HEAT mode for 2 3 hours to remove moisture left in the internal parts thoroughly to prevent m...

Страница 14: ...31 Abnormal swimming pool sensor H 32 Outdoor heat exchanger temperature sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code Dia...

Страница 15: ...e symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved Information ...

Страница 16: ...Printed in Malaysia ACXF55 11360 SM0717 0 Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2017 ...

Отзывы: