77
5 Customization list table:
Note: The functions described in the table may not be applicable to the model and may subject to change without
further notice.
Customization
Options Remark
No Name
Customer
Zone
1
Remote control number selection
A, B, C, D
2
Solar radiation sensitivity level adjustment
1, 2, 3, 4, 5
3
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [Low2]
16°C ~ [High2]
4
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [High2]
[Low2] ~ 30°C
5
Heat mode set temperature Low1 selection
16°C ~ [High1]
6
Heat mode set temperature High1 selection
[Low1] ~ 30°C
7
Filter cleaning selection
00 – Disable
01 – Enable
8
nanoe/nanoe-G default ON selection
00 – Disable
01 – Enable
9
Dust sensor monitoring & LED selection
00 – Disable
01 – Enable
10
Auto restart selection
00 – Disable
01 – Enable
11
Dust sensor sensitivity level adjustment
1, 2, 3
12 ~ 49 Reserve
Service
Zone
50
ECO demo ON
None (No display)
51
Light sensor check
None (No display)
52
nanoe-G / ECO sensor check
None (No display)
53
DOA check
None (No display)
54
Odor cut control selection
00 – Disable
01 – Enable
55
Frequency tolerance selection
03 – ±3Hz
07 – ±7Hz
56
Fixed fan speed selection during heat mode compressor OFF
00 – Disable
01 – Enable
57
nanoe check
None (No display)
58
Heat mode thermo shift adjustment
-3°C ~ 3°C
59
Others (Cool & Dry) mode thermo shift adjustment
-3°C ~ 3°C
60
Deice start determination judgment temperature switching
00 – No
01 – Yes
61
Cool mode disable selection
00 – No
01 – Yes
62
Heat mode disable selection
00 – No
01 – Yes
63
Base pan heater selection
A – Base pan A
b – Base pan B
64
Disable fan speed reduction during cool mode thermo-Off
00 – No
01 – Yes
65
LED smart OFF selection
00 – Disable
01 – Enable
66
nanoe-G ON/OFF duration selection
01 – Pattern 1
02 – Pattern 2
03 – Pattern 3
04 – Pattern 4
67
Operation OFF deice function selection
00 – Disable
01 – Enable
68
Compressor frequency change speed selection
01 – Pattern 1
02 – Pattern 2
03 – Pattern 3
69
Up/Down air swing upper limit restriction selection
00 – Disable
01 – Enable
70
Failure diagnosis mode disable
None (No display)
71
Compressor Fhmax setting selection
01 – Offset 1
02 – Offset 2
03 – Offset 3
72 ~ 99 Reserve