16
Indoor CS-E24PKEW
CS-E28PKES
Model
Outdoor CU-E24PKE
CU-E28PKE
Type
Hermetic Motor (Rotary)
Hermetic Motor (Rotary)
Motor Type
Brushless (4 poles)
Brushless (4 poles)
Compressor
Output Power
W
1.7k
1.7k
Type
Cross-Flow Fan
Cross-Flow Fan
Material
ASG33
ASG33
Motor Type
DC / Transistor (8-poles)
DC / Transistor (8-poles)
Input Power
W
104.0
104.0
Output Power
W
40
40
Cool rpm
880
880
QLo
Heat rpm
990
990
Cool rpm
1020
1020
Lo
Heat rpm
1100
1100
Cool rpm
1140
1180
Me
Heat rpm
1230
1250
Cool rpm
1270
1350
Hi
Heat rpm
1360
1400
Cool rpm
1340
1390
Indoor Fan
Speed
SHi
Heat rpm
1400
1430
Type
Propeller Fan
Propeller Fan
Material
PP
PP
Motor Type
DC (8-poles)
DC (8-poles)
Input Power
W
–
–
Output Power
W
60
60
Cool rpm
660
690
Outdoo
r Fa
n
Speed Hi
Heat rpm
640
650
Moisture Removal
L/h (Pt/h)
3.9 (8.2)
4.5 (9.5)
Cool m
3
/min (ft
3
/min)
13.40 (473)
13.40 (473)
QLo
Heat m
3
/min (ft
3
/min)
15.20 (537)
15.20 (537)
Cool m
3
/min (ft
3
/min)
15.70 (554)
15.70 (554)
Lo
Heat m
3
/min (ft
3
/min)
17.00 (600)
17.00 (600)
Cool m
3
/min (ft
3
/min)
17.81 (629)
18.50 (653)
Me
Heat m
3
/min (ft
3
/min)
19.10 (674)
19.40 (685)
Cool m
3
/min (ft
3
/min)
19.8 (700)
21.1 (745)
Hi
Heat m
3
/min (ft
3
/min)
21.2 (750)
21.9 (775)
Cool m
3
/min (ft
3
/min)
20.90 (738)
21.7 (767)
Indoor
Airflow
SHi
Heat m
3
/min (ft
3
/min)
21.90 (775)
22.4 (790)
Cool m
3
/min (ft
3
/min)
50.2 (1770)
54.4 (1925)
Outdoor
Airflow
Hi
Heat m
3
/min (ft
3
/min)
50.2 (1770)
54.4 (1925)
Control Device
Capillary Tube
Expansion Valve
Refrigerant Oil
cm
3
FV50S (800)
FV50S (800)
Refrigeration
Cycle
Refrigerant Type
g (oz)
R410A, 1.80k (63.5)
R410A, 1.80k (63.5)
Height (I/D / O/D)
mm (inch)
295 (11-5/8) / 795 (31-5/16)
295 (11-5/8) / 795 (31-5/16)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
1070 (42-5/32) / 875 (34-15/32)
Dimension
Depth (I/D / O/D)
mm (inch)
255 (10-1/16) / 320 (12-5/8)
255 (10-1/16) / 320 (12-5/8)
Weight
Net (I/D / O/D)
kg (lb)
13 (29) / 67 (148)
13 (29) / 67 (148)
Содержание CS-E7PKEW
Страница 28: ...28 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 29: ...29 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E7PK CS E9PK CS E12PK CS E15PK CS XE7PK CS XE9PK CS XE12PK CS XE15PK ...
Страница 30: ...30 5 1 2 CS E18PK CS E21PK CS E24PK CS E28PK CS XE18PK CS XE21PK ...
Страница 31: ...31 5 2 Outdoor Unit 5 2 1 CU E7PKE CU E9PKE 5 2 2 CU E12PKE CU E15PKE ...
Страница 32: ...32 5 2 3 CU E18PKE CU E21PKE ...
Страница 33: ...33 5 2 4 CU E24PKE CU E28PKE ...
Страница 42: ...42 8 1 2 CS E28PKES ...
Страница 48: ...48 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Страница 56: ...56 10 1 6 Human Activity Sensor Printed Circuit Board ...
Страница 57: ...57 10 2 Outdoor Unit 10 2 1 CU E7PKE ...
Страница 58: ...58 10 2 2 CU E9PKE CU E12PKE CU E15PKE ...
Страница 59: ...59 10 2 3 CU E18PKE CU E21PKE ...
Страница 60: ...60 10 2 4 CU E24PKE CU E28PKE ...
Страница 66: ...66 ...
Страница 68: ...68 For Gas side piping please refer table and diagram below ...
Страница 76: ...76 ...
Страница 140: ...140 Figure 3 Figure 4 18 1 1 3 To remove discharge grille Figure 5 ...
Страница 141: ...141 18 1 1 4 To remove control board Figure 6 18 1 1 5 To remove cross flow fan and indoor fan motor Figure 7 ...
Страница 142: ...142 Figure 8 Figure 9 ...
Страница 143: ...143 Figure 10 ...
Страница 145: ...145 18 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 Figure 16 ...
Страница 147: ...147 Figure 20 Figure 21 ...
Страница 148: ...148 Figure 22 ...