28
11.2.
Indoor Unit
11.2.1.
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent
it from the vibration.
The centre of installation plate should be at more than
at
right and left of the wall.
The distance from installation plate edge to ceiling should more
than .
From installation plate left edge to unit’s left side is .
From installation plate right edge to unit’s right is .
1. Mount the installation plate on the wall with 5 screws or
more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
• Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Line according to the left and right side of the installation
plate. The meeting point of the extended line is the
centre of the hole. Another method is by putting
measuring tape at position as shown in the diagram
above. The hole centre is obtained by measuring the
distance namely 128 mm for left and right hole
respectively.
• Drill the piping hole at either the right or the left and the
hole should be slightly slanting to the outdoor side.
11.2.2.
To Drill a Hole in the Wall and Install
a Sleeve of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
11.2.3.
Indoor Unit Installation
Model
Dimension
RE18***,
RE24***,
RE28***
585 mm 82 mm 165 mm 158 mm 169 mm 219 mm
: For left side piping, piping connection for liquid should be about
from this line.
: For left side piping, piping connection for gas should be about
from this line.
Caution
When the wall is hollow, please be sure to use the sleeve for
tube ass’y to prevent dangers caused by mice biting the
connecting cable.
Содержание CS-E18JKEW
Страница 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Страница 11: ...11 5 2 Outdoor Unit 5 2 1 CU RE18JKE ...
Страница 12: ...12 5 2 2 CU RE24JKE ...
Страница 13: ...13 6 Refrigeration Cycle Diagram ...
Страница 14: ...14 7 Block Diagram 7 1 CS RE18JKE CU RE18JKE ...
Страница 15: ...15 7 2 CS RE24JKE CU RE24JKE ...
Страница 16: ...16 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU RE18JKE ...
Страница 18: ...18 8 2 2 CU RE24JKE ...
Страница 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Страница 20: ...20 9 2 Outdoor Unit 9 2 1 CU RE18JKE ...
Страница 21: ...21 9 2 2 CU RE24JKE ...
Страница 22: ...22 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 23: ...23 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Страница 24: ...24 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU RE18JKE ...
Страница 25: ...25 10 2 2 Main Printed Circuit Board 10 2 2 1 CU RE24JKE ...
Страница 26: ...26 10 2 3 Power Printed Circuit Board 10 2 3 1 CU RE24JKE ...
Страница 29: ...29 1 For the right rear piping 2 For the right and right bottom piping 3 For the embedded piping ...
Страница 76: ...76 16 1 3 To remove power electronic controller ...
Страница 77: ...77 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Страница 78: ...78 16 1 6 To remove cross flow fan and indoor fan motor ...
Страница 79: ...79 ...
Страница 90: ...90 18 Exploded View and Replacement Parts List 18 1 Indoor Unit ...