a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c.
Timer “off” activates.
d. Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except fan only mode.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.
C. Control contents
a. Fan Speed manual
1. Fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2. Fan speed for quiet operation is -100 rpm from setting fan speed.
3. Fan Speed Auto
•
If FM
Lo
-100 rpm reduce from normal Heating Auto Fan Speed
•
If FM
Lo
maintain RPM
Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.
10.1.4. Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature quickly.
(a) Cooling Operation
(b) Soft Dry Operation
(c) Heating Operation
29
CS-E18EKU CU-E18EKU / CS-E21EKU CU-E21EKU
Содержание CS-E18EKU
Страница 10: ...4 Dimension 4 1 Indoor Unit Remote Control 10 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 11: ...4 2 Outdoor Unit 11 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 12: ...5 Refrigeration Cycle Diagram 12 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 13: ...6 Block Diagram 13 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 14: ...7 Wiring Diagram 7 1 CS E18EKU CS E21EKU 14 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 15: ...7 2 CU E18EKU CU E21EKU 15 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 16: ...8 1 Indoor Unit 8 Printed Circuit Board 16 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 17: ...8 2 Outdoor Unit 17 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...