11 Servicing Mode
11.1. Auto Switch Operation
The below operations will be performed by pressing the “AUTO” switch.
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto Switch is pressed and release before 5 sec..
2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to below 8 sec. A
“beep” sound will occur at the fifth sec., in order to identify the starting of Test Run operation.
3. HEATING TRIAL OPERATION
Press the AUTO switch continuously for more than 8 sec. to below 11 sec. and release when a “pep pep” sound is heard
at eight sec. (However, a “beep” sound is occurred at fifth sec..) then press Remote controller “A/C Reset” button once.
Remote controller signal will activate operation to force heating mode.
4. REMOTE CONTROLLER RECEIVING SOUND ON/OFF
The ON/OFF of Remote controller receiving sound can be change over by following steps:
a. Press “AUTO” Switch continuously for more than 16 sec. to below 21 sec.
A “beep”,“beep”,“beep”,“beep” sound will occur at the sixteenth sec..
b. Press the “A/C Reset” button once. Remote controller signal will activate the Remote controller sound setting mode.
c.
Press the “Check” button once at Remote controller. A “beep” sound will occur.
d. Press the “AUTO” switch once to select Remote controller receiving sound ON/OFF. A “beep” sound indicates receiving
sound ON, and a long “beep” sound indicates receiving sound OFF.
11.2. Indicator Panel
LED
POWER
TIMER
QUIET
POWERFUL
Color
Green
Orange
Orange
Orange
Light ON
Operation ON
Timer Setting ON
Quiet Mode ON
Powerful Mode ON
Light OFF
Operation OFF
Timer Setting OFF
Quiet Mode OFF
Powerful Mode OFF
Note:
•
If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode
judgment, or ON timer sampling.
•
If Timer LED is blinking, there is an abnormality operation occurs.
33
CS-E18EKU CU-E18EKU / CS-E21EKU CU-E21EKU
Содержание CS-E18EKU
Страница 10: ...4 Dimension 4 1 Indoor Unit Remote Control 10 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 11: ...4 2 Outdoor Unit 11 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 12: ...5 Refrigeration Cycle Diagram 12 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 13: ...6 Block Diagram 13 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 14: ...7 Wiring Diagram 7 1 CS E18EKU CS E21EKU 14 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 15: ...7 2 CU E18EKU CU E21EKU 15 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 16: ...8 1 Indoor Unit 8 Printed Circuit Board 16 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...
Страница 17: ...8 2 Outdoor Unit 17 CS E18EKU CU E18EKU CS E21EKU CU E21EKU ...