21
9.2 Outdoor
Unit
Resistance of Compressor Windings
MODEL
CU-CZ25/35ZKE
CONNECTION
9RD132XGB21
U-V
1.708 Ω
U-W
1.708 Ω
V-W
1.708 Ω
Note: Resistance at 20°C of ambient temperature.
FUSE 3
T3.15A L250V
IC19
28
1
2
11
FUSE 2
T3.15A L250V
FUSE 1
(20A 250V)
FUSE 5
(20A 250V)
REACTOR
GRY
RAT1
(GRY)
RAT2
(GRY)
CN-TH1
(WHT)
CN-TANK
(WHT)
CN-HOT
(WHT)
OUTDOOR AIR TEMP. SENSOR
(THERMISTOR)
COMPRESSOR TEMP. SENSOR
(THERMISTOR)
ELECTRO-MAGNETIC
COIL (4-WAY VALVE)
ELECTRO-MAGNETIC
COIL (EXPANSION VALVE)
COMPRESSOR
FAN MOTOR
CN-MTR2
(WHT)
PIPING TEMP. SENSOR
(THERMISTOR)
GRY
FUSE 4
(20A 250V)
DATA
(BLK)
AC-BRW
(BRW)
AC-BLU
(BLU)
FG1
(GRN)
GRN
GRN
FG2
(GRN)
SOUND PROOF
BOARD
CN-STM1
(WHT)
U (RED)
RED
V (BLU)
BLU
W (YLW)
YLW
BASE PAN
HEATER
ELECTRONIC CONTROLLER (MAIN)
BLU
BLU
HT2 (BLU)
ACN2 (BLU)
RY-HT2
TERMINAL
BOARD
T
O INDOOR UNIT
2
1
3
BLK
BRW
BLU
BLU
N
L
GROUNDING TERMINAL
BRW
YLW/GRN
SINGLE PHASE
POWER SUPPLY