31
WARNING
This equipment must be properly earthed.
Note:
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
12.2.4.1 Wire Stripping and Connecting Requirement
Recommended
length (mm)
Connection cable
Tape
3
a
b
c
d
Terminal Board
Holder
Earth Wire
longer than
others AC
wires for
safety reason
Indoor & outdoor
connection cable
Outdoor Unit
Recommended
length (mm)
a
b
c
d
40 40
50
70
Do not joint wires.
OR
WARNING
RISK OF FIRE
JOINING OF WIRES MAY
CAUSE OVERHEATING
AND FIRE.
OR
OR
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national wiring rules.
5 mm or more
Indoor/outdoor
connection
terminal board
(gap between wires)
No loose strand
when inserted
10 ± 1 mm
Wire stripping
Conductor fully
inserted
Conductor over
inserted
Conductor not
fully inserted
ACCEPT
PROHIBITED
PROHIBITED