![Panasonic CS-C7MKP-7 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/panasonic/cs-c7mkp-7/cs-c7mkp-7_service-manual_3948657080.webp)
80
17.2.2
CS-C9MKP-7 CU-C9MKP-7
Cooling
Characteristic
o
Room temperature:
27°C (DBT), 19°C (WBT)
o
Operation condition:
High fan speed
o
Piping
length:
7.5m
15.000
15.200
15.400
15.600
15.800
16.000
30
31
32
33
34
35
36
37
38
39
40
Outdoor Air Temperature (°C)
Ou
tle
t A
ir
T
e
m
p
e
rat
ur
e
(
°C
)
220
240
2.400
2.500
2.600
2.700
2.800
2.900
30
31
32
33
34
35
36
37
38
39
40
Outdoor Air Temperature (°C)
Co
o
lin
g
C
apa
c
ity
(
k
W
)
3.400
3.600
3.800
4.000
4.200
30
31
32
33
34
35
36
37
38
39
40
Outdoor Air Temperature (°C)
C
u
rre
n
t
(A
)
0.520
0.530
0.540
0.550
0.560
30
31
32
33
34
35
36
37
38
39
40
Outdoor Air Temperature (°C)
Ga
s S
id
e
P
ipi
ng
P
res
s
u
re
(
M
P
a
)
Содержание CS-C7MKP-7
Страница 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C7MKP 7 CS C9MKP 7 CS C12MKP 7 ...
Страница 14: ...14 5 1 2 CS C18MKP 7 CS C24MKP 7 ...
Страница 15: ...15 5 2 Outdoor Unit 5 2 1 CU C7MKP 7 CU C9MKP 7 CU C12MKP 7 5 2 2 CU C18MKP 7 ...
Страница 16: ...16 5 2 3 CU C24MKP 7 ...
Страница 17: ...17 6 Refrigeration Cycle Diagram ...
Страница 18: ...18 7 Block Diagram 7 1 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Страница 19: ...19 7 1 2 CS C18MKP 7 CU C18MKP 7 CS C24MKP 7 CU C24MKP 7 ...
Страница 23: ...23 9 Electronic Circuit Diagram 9 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Страница 24: ...24 9 2 CS C18MKP 7 CU C18MKP 7 ...
Страница 25: ...25 9 3 CS C24MKP 7 CU C24MKP 7 ...
Страница 27: ...27 10 1 1 2 CS C18MKP 7 CS C24MKP 7 10 1 2 Indicator Printed Circuit Board ...
Страница 29: ...29 10 1 6 Human Activity Sensor Printed Circuit Board ...
Страница 39: ...39 12 1 2 Cooling Operation Time Diagram For CS C18MKP 7 CU C18MKP 7 and CS C24MKP 7 CU C24MKP 7 ...
Страница 41: ...41 12 2 2 Soft Dry Operation Time Diagram For CS C18MKP 7 CU C18MKP 7 and CS C24MKP 7 CU C24MKP 7 ...
Страница 70: ...70 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5 ...
Страница 72: ...72 Figure 9 Figure 10 ...
Страница 74: ...74 16 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 ...
Страница 76: ...76 Figure 19 Figure 20 Figure 21 ...
Страница 77: ...77 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...