Error Detection Control
When e-ion indicator blink, it indicates error listed below:
o
Active e-ion Air Purifying system PCB main connector open:
Judgment
Method
During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main
connector to PCB is opened.
Troubleshooting
Methods
Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.
o
Abnormal Discharge error:
Judgment
Method
During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal
discharge and stops power supplies to the Active e-ion Air Purifying system.
Abnormal discharge is caused by ionizer or filter’s high voltage power supply short-circuits due to
water or dust adhesion, and so forth.
When abnormal discharge occurred, every 30 minutes the unit supplies power to the Active e-ion Air
Purifying system.
When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for
e-ion Check Mode, where the error will shows immediately despite the 24 times counter)
Troubleshooting
Method
Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation and check the Active e-ion
Air Purifying system main connector to PCB.
After that, press “e-ion” button again to confirm the e-ion indicator not blinking.
The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.
Error
Reset
Method
Press “OFF/ON” button to OFF the operation.
Press AUTO OFF/ON button at indoor unit to OFF the operation.
OFF Timer activates
Power supply reset
o
Active e-ion Air Purifying system breakdown error:
Judgment
Method
When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, Active e-ion Air
Purifying system breakdown error shows immediately.
It is due to indoor PCB or filter’s high voltage power supply damage.
Operations except e-ion continue. Both Timer indicator and e-ion indicator blink.
Troubleshooting
Method
Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation.
Change main circuit board or filter’s high voltage power supply.
When lo-feedback voltage supplied to Active e-ion Air Purifying system during e-ion operation, e-ion
indicator and Timer indicator stop blinking.
Содержание CS-C7MKP-7
Страница 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C7MKP 7 CS C9MKP 7 CS C12MKP 7 ...
Страница 14: ...14 5 1 2 CS C18MKP 7 CS C24MKP 7 ...
Страница 15: ...15 5 2 Outdoor Unit 5 2 1 CU C7MKP 7 CU C9MKP 7 CU C12MKP 7 5 2 2 CU C18MKP 7 ...
Страница 16: ...16 5 2 3 CU C24MKP 7 ...
Страница 17: ...17 6 Refrigeration Cycle Diagram ...
Страница 18: ...18 7 Block Diagram 7 1 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Страница 19: ...19 7 1 2 CS C18MKP 7 CU C18MKP 7 CS C24MKP 7 CU C24MKP 7 ...
Страница 23: ...23 9 Electronic Circuit Diagram 9 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Страница 24: ...24 9 2 CS C18MKP 7 CU C18MKP 7 ...
Страница 25: ...25 9 3 CS C24MKP 7 CU C24MKP 7 ...
Страница 27: ...27 10 1 1 2 CS C18MKP 7 CS C24MKP 7 10 1 2 Indicator Printed Circuit Board ...
Страница 29: ...29 10 1 6 Human Activity Sensor Printed Circuit Board ...
Страница 39: ...39 12 1 2 Cooling Operation Time Diagram For CS C18MKP 7 CU C18MKP 7 and CS C24MKP 7 CU C24MKP 7 ...
Страница 41: ...41 12 2 2 Soft Dry Operation Time Diagram For CS C18MKP 7 CU C18MKP 7 and CS C24MKP 7 CU C24MKP 7 ...
Страница 70: ...70 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5 ...
Страница 72: ...72 Figure 9 Figure 10 ...
Страница 74: ...74 16 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 ...
Страница 76: ...76 Figure 19 Figure 20 Figure 21 ...
Страница 77: ...77 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...