Height(I/D / O/D)
mm (inch)
290 (11-7/16)
510 (20-3/32)
Width (I/D / O/D)
mm (inch)
870 (34-9/32)
650 (25-19/32)
Dimension
Depth (I/D / O/D)
mm (inch)
204 (8-1/16)
230 (9-1/16)
Weight
Net (I/D / O/D)
kg (lb)
9 (20)
25 (55)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
Standard length
m (ft)
7.5 (24.6)
Length range (min – max)
m (ft)
3 (9.8 ) ~ 15 (49.2)
I/D & O/D Height different
m (ft)
5 (16.4)
Additional Gas Amount
g/m (oz/ft)
10 (0.1)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
Inner Diameter
mm
16.2
Drain Hose
Length mm
550
Fin Material
Aluminium (Pre coated)
Fin Type
Slit fin
Row x Stage x FPI
2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
Fin Material
Aluminium (Blue Coated)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 23 x 17
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
25.4 x 483 x 582:562
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Indoor
Power Supply Cord
A
10
Thermostat
-
Protection Device
2-Stage Overload Protector
DRY BULB
WET BULB
Maximum 32
23
Indoor Operation Range
Minimum 16
11
Maximum 43
26
Outdoor Operation Range
Minimum 16
11
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Specifications are subjected to change without prior notice for further improvement.
Содержание CS-C7MKP-7
Страница 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C7MKP 7 CS C9MKP 7 CS C12MKP 7 ...
Страница 14: ...14 5 1 2 CS C18MKP 7 CS C24MKP 7 ...
Страница 15: ...15 5 2 Outdoor Unit 5 2 1 CU C7MKP 7 CU C9MKP 7 CU C12MKP 7 5 2 2 CU C18MKP 7 ...
Страница 16: ...16 5 2 3 CU C24MKP 7 ...
Страница 17: ...17 6 Refrigeration Cycle Diagram ...
Страница 18: ...18 7 Block Diagram 7 1 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Страница 19: ...19 7 1 2 CS C18MKP 7 CU C18MKP 7 CS C24MKP 7 CU C24MKP 7 ...
Страница 23: ...23 9 Electronic Circuit Diagram 9 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Страница 24: ...24 9 2 CS C18MKP 7 CU C18MKP 7 ...
Страница 25: ...25 9 3 CS C24MKP 7 CU C24MKP 7 ...
Страница 27: ...27 10 1 1 2 CS C18MKP 7 CS C24MKP 7 10 1 2 Indicator Printed Circuit Board ...
Страница 29: ...29 10 1 6 Human Activity Sensor Printed Circuit Board ...
Страница 39: ...39 12 1 2 Cooling Operation Time Diagram For CS C18MKP 7 CU C18MKP 7 and CS C24MKP 7 CU C24MKP 7 ...
Страница 41: ...41 12 2 2 Soft Dry Operation Time Diagram For CS C18MKP 7 CU C18MKP 7 and CS C24MKP 7 CU C24MKP 7 ...
Страница 70: ...70 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5 ...
Страница 72: ...72 Figure 9 Figure 10 ...
Страница 74: ...74 16 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 ...
Страница 76: ...76 Figure 19 Figure 20 Figure 21 ...
Страница 77: ...77 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...