35
• Airflow direction (Horizontal, Vertical) Control
- During any operation mode combines with Patrol operation, airflow direction follows respective operation mode.
- During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
- During Patrol individual operation if e-ion stops, Airflow direction louver closed.
- Indicator
- When Patrol operation starts, Patrol LED is ON with 3 different colors:
- Then e-ion operation starts based on dirtiness level, both Patrol LED and e-ion LED are ON.
- Remote Control Receiving Sound
- Timer Control
- When ON timer activates when unit stops, previous operation resumes without Patrol operation.
- When ON timer activates during any operation, no change and carry on current operation.
- When OFF timer activates during any operation, all operation stops.
- Power Failure Control
- During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes
immediately.
- During combination operation, if power failure occurs, after power resumes combination operation resume immediately.
- Error Detection Control
- The Patrol error detection control starts once the power is supplied to Patrol sensor. However, the error will display when
the Patrol operation is ON.
- Error detection method:
1. If the Patrol sensor is opened circuit continuously for 6 hours, Patrol sensor error occurs. However, the error will
display only when the Patrol operation is ON.
- Patrol Sensor Control after error occurs.
1. During any operation mode combines with Patrol operation.
a. Power supply to Patrol sensor is OFF.
b. Air conditioner normal mode operation continues with Patrol LED blinking.
c. The Patrol LED continues blinking if the patrol operation is ON and stops blinking if the Patrol operation is OFF.
- During Patrol individual mode.
1. Power supply to Patrol sensor is OFF.
2. Patrol LED blinks.
3. The Patrol LED continues blinking if the patrol operation is ON and stops blinking if the Patrol operation is OFF.
- Error cancel condition:
1. Power supply reset.
Patrol LED
Air Quality
Blue
Clean
Orange
Moderate
Red
Dirty
•
Normal Operation
o
Patrol Mode
: Beep
•
Patrol Mode
o
Stop
: Long Beep
•
Patrol Mode
o
Normal Operation
: Beep
•
Stop
o
Patrol
: Beep
Содержание CS-C12HKF
Страница 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12HK ...
Страница 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12HK ...
Страница 11: ...11 6 Refrigeration Cycle Diagram ...
Страница 12: ...12 7 Block Diagram ...
Страница 14: ...14 9 Electronic Circuit Diagram ...
Страница 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board TOP VIEW ...
Страница 16: ...16 BOTTOM VIEW ...
Страница 17: ...17 10 1 2 Power Printed Circuit Board TOP VIEW BOTTOM VIEW ...
Страница 18: ...18 10 1 3 Indicator TOP VIEW BOTTOM VIEW ...
Страница 46: ...46 ...
Страница 47: ...47 16 1 3 To remove discharge grille 16 1 4 To remove control board ...
Страница 48: ...48 16 1 5 To remove cross flow fan and indoor fan motor ...
Страница 49: ...49 ...
Страница 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Страница 51: ...51 17 2 Operation Characteristics 17 2 1 CS C12HK CU C12HK ...
Страница 52: ...52 ...
Страница 54: ...54 ...