13 Protection Control
13.1. Restart Control (Time Delay Safety Control)
•
When the thermo-off temperature (temperature which compressor stops to operate) is reached during:-
- Cooling operation - the compressor stops for 3 minutes (minimum) before resume operation.
- Soft Dry operation - the compressor stops for 6 minutes (minimum) before resume operation.
• If the operation is stopped by the remote control, the compressor will not turn on within 3 minutes from the moment operation
stop, although the unit is turn on again within the period.
•
This phenomenon is to balance the pressure inside the refrigerant cycle.
13.2. 7 Minutes Time Save Control
•
The compressor will start automatically if it has stopped for 7 minutes and the intake air temperature falls between the
compressor ON temperature (A) and compressor OFF temperature (B) during the period.
• This phenomenon is to reduce the built up humidity inside a room.
13.3. 60 Seconds Forced Operation
•
Once the air conditioner is turned on, the compressor will not stop within 60 seconds in a normal operation although the intake air
temperature has reached the thermo-off temperature. However, force stop by pressing the OFF/ON operation button at the
remote control is permitted.
•
The reason for the compressor to force operate at minimum 60 seconds is to allow the refrigerant oil run in a full cycle and return
back to the outdoor unit.
13.4. Starting current Control
•
When the compressor, outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will start to
operate at 1.6 second later.
•
The reason of the difference is to reduce the starting current flow.
13.5. Freeze Preventive Control
• To protect indoor heat exchanger from freezing and to prevent higher volume of refrigerant in liquid form return to compressor.
• This control will activate when the temperature of indoor heat exchanger falls below 2
q
C continuously for more than 4 minutes.
• The current fan speed will change to freeze prevention speed after 70 seconds compressor on. When indoor pipe temperature
reaches certain temperature for 5 sec. the speed will be increased as in below figure.
• Compressor will turn off when indoor temperature falls below 2
q
C for more than 4 minutes. It will restart again when indoor heat
exchanger temperature rises to 10
q
C.
• Restart control (Time Delay Safety Control) will be applied in this control.
Содержание CS-C12HKF
Страница 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12HK ...
Страница 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12HK ...
Страница 11: ...11 6 Refrigeration Cycle Diagram ...
Страница 12: ...12 7 Block Diagram ...
Страница 14: ...14 9 Electronic Circuit Diagram ...
Страница 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board TOP VIEW ...
Страница 16: ...16 BOTTOM VIEW ...
Страница 17: ...17 10 1 2 Power Printed Circuit Board TOP VIEW BOTTOM VIEW ...
Страница 18: ...18 10 1 3 Indicator TOP VIEW BOTTOM VIEW ...
Страница 46: ...46 ...
Страница 47: ...47 16 1 3 To remove discharge grille 16 1 4 To remove control board ...
Страница 48: ...48 16 1 5 To remove cross flow fan and indoor fan motor ...
Страница 49: ...49 ...
Страница 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Страница 51: ...51 17 2 Operation Characteristics 17 2 1 CS C12HK CU C12HK ...
Страница 52: ...52 ...
Страница 54: ...54 ...