background image

8

ENGLISH

Pre-season Inspection

Clean the air filters, re-insert and operate the air
conditioners

Is the discharged air cold / warm?

Operation is normal if 15 minutes after the start of
operation, the difference between the air intake and
outlet vents temperature is:-

Are the air intake or outlet vents of the indoor or
outdoor units obstructed?

Are the remote control batteries weak?

If the remote control display appears weak, replace
the batteries.

When the Air Conditioner is Not Used
for an Extended Period of Time

1

To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:-

2

Turn off the power supply and unplug.

3

Remove the remote control batteries.

Recommended Inspection

• After used over several seasons, the unit will

become dirty and thus decreases the unit’s
performance. Depending on the operation
conditions, a dirty unit may produce odour and dust
may pollute dehumidification system. Therefore, a
seasonal inspection is recommended in addition to
regular cleaning. (Consult an authorized dealer).

COOL – 8°C or above
HEAT – 14°C or above

HELPFUL INFORMATION

Auto Operation

Automatic Operation

• If the remote control fails to function or has been

misplaced, press the Auto Operation button to start
the Automatic operation.

• The Automatic operation will be activated

immediately once the Auto operation button is
pressed. However, temperature cannot be adjusted
in this operation.

• The power indicator on the indoor unit will blink until

the operation mode is selected automatically.

• To cancel this operation, press once more.

Timer Setting

• When power failure occurs, the timer setting will be

cancelled. Once power is resumed, reset the timer.

Thunder and Lightning

• This air conditioner is equipped with a built-in surge

protective device. However, in order to further
protect your air conditioner from being damaged by
abnormally strong lightning activity, you may switch
off the main power supply and unplug from power
socket.

ENERGY SAVING AND OPERATION
HINTS

Setting the Temperature

• Approximately 10% of electricity can be saved.
• Set the temperature higher or lower than the

desired temperature.

Air Filters

• Clean the air filters every 2 weeks.
• Dirty filters may reduces cooling or heating

efficiency.

Keep All Doors and Windows Closed

• Otherwise, cooling or heating performance will be

reduced and electricity cost is wasted.

Outdoor Unit

• Do not block the air outlet vents. Otherwise, it will

lower the cooling or heating performance.

Timer and Sleep Mode

• To prevent wastage of electricity, use sleep mode

when sleeping or Timer when going out.

Avoid Direct Sunlight

• Keep curtains or drapes closed to avoid direct

sunlight during cooling operation.

COOL operation with
30°C set temperature

Cooling Operation : 1°C higher
Heating Operation : 2°C lower

AUTO
OFF/ON

Press the Auto Operation Button

Содержание CS-A12ATP5

Страница 1: ... CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ENGLISH P 1 P 9 F563422 Before using your air conditioner please read this operating instructions carefully and keep it for future reference OPERATING INSTRUCTIONS Room Air Conditioner ...

Страница 2: ...milarly qualified person in order to avoid a hazard 2 Remove power plug or disconnect from the main before servicing this appliance 3 Do not repair by yourself In case of malfunction of this appliance do not repair by yourself Contact the sales dealer or service dealer for a repair 4 The appliance is not intended for use by young children or infirm persons without supervision 5 Young children shou...

Страница 3: ...ch off and unplug the power supply Caution This sign warns of injury Do not pull the cord to disconnect the plug Do not wash the unit with water Do not use for other purposes such as preservation Do not use any combustible equipment at airflow direction Do not sit or place anything on the outdoor unit Switch off the power supply before cleaning Ventilate the room regularly Pay attention as to whet...

Страница 4: ...2 Power Indicator GREEN 3 Timer Mode Indicator ORANGE 4 Air Swing Mode Indicator RED 5 Sleep Mode Indicator ORANGE Outdoor Unit 1 Air Intake Vents 2 Piping 3 Drain Hose 4 Connecting Cable 5 Air Outlet Vents Accessories Remote Control Remote Control Holder Two RO3 AAA dry cell batteries or equivalent OFF O N TEMP MODE FA N SP EE D AU TO TIMER AIR SW ING ON OFF SE T C MAN UA L RE SE T SL EE P AU TO ...

Страница 5: ...be used for a long period Proper way to operate the remote control in the case of ceiling wall mounting Operate the remote control in parallel with the floor See the figure below 1 Signal Transmitter 2 Operation Display 3 Room Temperature Setting Button self illuminating button 4 Operation Mode Selection Button 5 Sleep Mode Operation Button self illuminating button 6 Timer Setting Button 7 Timer S...

Страница 6: ...AUTO Operation press 3 to select Operation with 2 C higher than the standard temperature Operation with the standard temperature Operation with 2 C lower than the standard temperature Standard Temperature At the beginning of the automatic operation Heating Cooling or Soft Dry is automatically selected according to the indoor temperature After the operation mode has been selected the mode does not ...

Страница 7: ...adjusted as desired by using the remote control This is effective when you want to cool yourself directly such as when coming out of the bath The louver can be adjusted within a range between the horizontal and 30 degrees downward at Cooling and Soft Dry Operation and between the horizontal and 60 degrees downward at Heating Operation Automatic Operation Press the Auto Airflow Direction Button 6 C...

Страница 8: ... press the Timer Setting Button 2 or 3 to the desired number of hours Press the Timer Set Cancel Button 4 1 hour Sleep shift operation starts Approx 3 C decrease Cooling or Soft Dry Operation for sleep shift operation will start to avoid overcooling Heating operation for sleep shift operation will start to avoid overheating Sleep Operation button is pressed 0 1 hour Approx 2 C decrease Approx 1 C ...

Страница 9: ...y once the Auto operation button is pressed However temperature cannot be adjusted in this operation The power indicator on the indoor unit will blink until the operation mode is selected automatically To cancel this operation press once more Timer Setting When power failure occurs the timer setting will be cancelled Once power is resumed reset the timer Thunder and Lightning This air conditioner ...

Страница 10: ...is the answer This is to protect the air conditioner Wait until the air conditioner begins to operate This is the sound of refrigerant flowing inside the air conditioner Condensation occurs when the airflow from the air conditioner cools the room This may be a damp smell emitted by the wall carpet furniture or clothing in the room In COOL DRY operation moisture in the air condenses into water on t...

Страница 11: ...ita Electric Industrial Co Ltd Web Site http www panasonic co jp global F563422 Printed in Malaysia P0112 2 Please remember to record the following Model Number Serial Number Dealer s Name Date Purchased Note ...

Отзывы: