6
ENGLISH
●
Operation Details
COOL – Cooling Operation
•
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
•
Sense indoor temperature to select the optimum
mode.
•
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
•
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
•
During Soft Dry operation, the indoor fan operates at
Low fan speed for 10 minutes (ON and OFF for 4
seconds intervals) then OFF for 6 minutes. This
operation will be repeated.
HEAT – Heating Operation
•
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
•
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
■
Setting the Fan Speed
• Press
4
to select:-
– Low Fan Speed
– Medium Fan Speed
– High Fan Speed
■
Vertical Airflow Direction
●
Manual Operation
•
Press and hold the Manual Airflow Direction
Selection Button
5
, then release at the desired
airflow direction
• Cooling / Soft Dry / Heating
The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 30 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
60 degrees downward at Heating Operation.
●
Automatic Operation
•
Press the Auto Airflow Direction Button
6
•
Cooling / Soft Dry
The louver will automatically swing up and down
to create the felling of a refreshing breeze.
•
Heating
■
Setting the Horizontal Airflow Direction
●
Use this air conditioner under the following
conditions:
●
Notes
•
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
•
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
• Adjust it manually
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
DBT
32
(30)
16
(16)
WBT
23
(-)
11
(-)
DBT
43
(24)
16
(-5)
WBT
26
(18)
11
(-6)
Indoor
Outdoor
Unit in °C
Horizontal
Downward
Swing up
and down
Horizontal
Downward
When the airflow
temperature is low
When the airflow
temperature become warm