Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.

During Soft Dry operation, the indoor fan operates at
Low fan speed for 10 minutes (ON and OFF for 4
seconds intervals) then OFF for 6 minutes. This
operation will be repeated.

HEAT – Heating Operation

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.

Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.

Setting the Fan Speed

• Press 

4

 to select:-

– Low Fan Speed
– Medium Fan Speed
– High Fan Speed

Vertical Airflow Direction

Manual Operation

Press and hold the Manual Airflow Direction
Selection Button 

5

 , then release at the desired

airflow direction

• Cooling / Soft Dry / Heating

The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 30 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
60 degrees downward at Heating Operation.

Automatic Operation

Press the Auto Airflow Direction Button 

6

Cooling / Soft Dry

The louver will automatically swing up and down
to create the felling of a refreshing breeze.

Heating

Setting the Horizontal Airflow Direction

Use this air conditioner under the following
conditions:

Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

• Adjust it manually

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

32

(30)

16

(16)

WBT

23
(-)

11
(-)

DBT

43

(24)

16

(-5)

WBT

26

(18)

11

(-6)

Indoor

Outdoor

Unit in °C

Horizontal

Downward

Swing up
and down

Horizontal

Downward

When the airflow
temperature is low

When the airflow
temperature become warm

Содержание CS-A12ATP5

Страница 1: ... CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ENGLISH P 1 P 9 F563422 Before using your air conditioner please read this operating instructions carefully and keep it for future reference OPERATING INSTRUCTIONS Room Air Conditioner ...

Страница 2: ...milarly qualified person in order to avoid a hazard 2 Remove power plug or disconnect from the main before servicing this appliance 3 Do not repair by yourself In case of malfunction of this appliance do not repair by yourself Contact the sales dealer or service dealer for a repair 4 The appliance is not intended for use by young children or infirm persons without supervision 5 Young children shou...

Страница 3: ...ch off and unplug the power supply Caution This sign warns of injury Do not pull the cord to disconnect the plug Do not wash the unit with water Do not use for other purposes such as preservation Do not use any combustible equipment at airflow direction Do not sit or place anything on the outdoor unit Switch off the power supply before cleaning Ventilate the room regularly Pay attention as to whet...

Страница 4: ...2 Power Indicator GREEN 3 Timer Mode Indicator ORANGE 4 Air Swing Mode Indicator RED 5 Sleep Mode Indicator ORANGE Outdoor Unit 1 Air Intake Vents 2 Piping 3 Drain Hose 4 Connecting Cable 5 Air Outlet Vents Accessories Remote Control Remote Control Holder Two RO3 AAA dry cell batteries or equivalent OFF O N TEMP MODE FA N SP EE D AU TO TIMER AIR SW ING ON OFF SE T C MAN UA L RE SE T SL EE P AU TO ...

Страница 5: ...be used for a long period Proper way to operate the remote control in the case of ceiling wall mounting Operate the remote control in parallel with the floor See the figure below 1 Signal Transmitter 2 Operation Display 3 Room Temperature Setting Button self illuminating button 4 Operation Mode Selection Button 5 Sleep Mode Operation Button self illuminating button 6 Timer Setting Button 7 Timer S...

Страница 6: ...AUTO Operation press 3 to select Operation with 2 C higher than the standard temperature Operation with the standard temperature Operation with 2 C lower than the standard temperature Standard Temperature At the beginning of the automatic operation Heating Cooling or Soft Dry is automatically selected according to the indoor temperature After the operation mode has been selected the mode does not ...

Страница 7: ...adjusted as desired by using the remote control This is effective when you want to cool yourself directly such as when coming out of the bath The louver can be adjusted within a range between the horizontal and 30 degrees downward at Cooling and Soft Dry Operation and between the horizontal and 60 degrees downward at Heating Operation Automatic Operation Press the Auto Airflow Direction Button 6 C...

Страница 8: ... press the Timer Setting Button 2 or 3 to the desired number of hours Press the Timer Set Cancel Button 4 1 hour Sleep shift operation starts Approx 3 C decrease Cooling or Soft Dry Operation for sleep shift operation will start to avoid overcooling Heating operation for sleep shift operation will start to avoid overheating Sleep Operation button is pressed 0 1 hour Approx 2 C decrease Approx 1 C ...

Страница 9: ...y once the Auto operation button is pressed However temperature cannot be adjusted in this operation The power indicator on the indoor unit will blink until the operation mode is selected automatically To cancel this operation press once more Timer Setting When power failure occurs the timer setting will be cancelled Once power is resumed reset the timer Thunder and Lightning This air conditioner ...

Страница 10: ...is the answer This is to protect the air conditioner Wait until the air conditioner begins to operate This is the sound of refrigerant flowing inside the air conditioner Condensation occurs when the airflow from the air conditioner cools the room This may be a damp smell emitted by the wall carpet furniture or clothing in the room In COOL DRY operation moisture in the air condenses into water on t...

Страница 11: ...ita Electric Industrial Co Ltd Web Site http www panasonic co jp global F563422 Printed in Malaysia P0112 2 Please remember to record the following Model Number Serial Number Dealer s Name Date Purchased Note ...

Отзывы: