For details about connection settings, please see the following illustrated manuals.
(IP Connection): “
Controlling AW-HE40 via AW-RP50 Controller
”
(Serial Connection):
“
Controlling AW-HE40 with AW-RP50 (via Serial Connection)
”
【
Controlling Multiple AW-HE40 Cameras via AW-RP50 Controller
】
Connecting multiple cameras is usually done by “AUTO SET IP” which is executed via AW-RP50
controller.
The controller detects the cameras in the same subnet (a range divided by a router), links them to the
camera numbers where [NoAsign] is set, and then automatically assigns pre-registered IP addresses to
those cameras.
Connection Setting: [SYSTEM] menu
>
[CAMERA CTL]
>
[CAM1
– 100]
⇒
[NoAsign]
IP Address Setting: [SYSTEM] menu
>
[CAM IP ADR]
>
[CAM1
– 100]
⇒
[Registered IP Address]
①
Press MENU button.
– (Fig. 3-A)
②
Press [10] SYSTEM button.
– (Fig. 3-B)
③
Turn F1 dial
– (Fig. 3-C) to select [5] AUTO SET IP.
④
Press F1 dial to make [RENEW IP ADR] appear on the lower half of the LCD screen.
*
If it does not appear, turn F2 dial
– (Fig. 3-D) to make [RENEW IP ADR] appear.
⑤
While [RENEW IP ADR] is displayed, press F2 dial. The number of units AW-RP50 has newly
detected and the number of units it currently manages (all the remote cameras and switchers) will be
displayed on the upper half of the LCD screen. (*1)
⑥
[NO] will be displayed on the lower half of the LCD screen. So, turn F2 dial to select [YES] and then
press F2 dial.
⑦
When [COMPLETE] is displayed on the lower half of the LCD screen, the setting-up is completed.
Example:
AW-RP50 detects Cameras A, B and C.
[CAMERA CTL] → [NoAsign] for all of [CAM1 – 3]
[CAM IP ADR] → If the following are IP addresses of [CAM1 – 3],
CAM1: 192. 168. 0. 10
CAM2: 192. 168. 0. 11
CAM3: 192. 168. 0. 12
IP addresses of the cameras are set up as follows.
Camera A: 192. 168. 0. 10 *Controlled via AW-RP50/CAM1
Camera B: 192. 168. 0. 11 *Controlled via AW-RP50/CAM2
Camera C: 192. 168. 0. 12 *Controlled via AW-RP50/CAM3