KW8M Eco-POWER METER (1A/5ACT input type)
17
VT ratio setting mode
Set VT ratio using <ITEM/
△
>, <SHIFT/
▽
>, < >, < >.
If the VT is 440/110, set to “4.00”.
Increase
value
Decrease
value
Shift place to set
(1.00
~
99.99)
Shift place to set
↓
<SET>
Current for time measurement setting mode
Set current for time measurement using <ITEM/
△
>, <SHIFT/
▽
>, < >, < >.
If you measure the current over 50.0%F.S, set to “50.0”.
Increase
value
Decrease
value
Shift place to set
(1.0
~
100.0)
Shift place to set
↓
<SET>
Cutoff current setting mode
Set cutoff current using <ITEM/
△
>, <SHIFT/
▽
>, < >, < >.
If you don’t measure the current under 10.0%F.S, set to “10.0”.
Increase
value
Decrease
value
Shift place to set
(1.0
~
50.0)
Shift place to set
↓
<SET>
ITEM
△
SHIFT
▽
ITEM
△
SHIFT
▽
ITEM
△
SHIFT
▽