Overview

This camera control unit (CCU) is designed to be used with the 

AK-HC3800 studio handy camera (sold separately).

Connect it to the studio handy camera (hereinafter referred to as the 

camera) with an optical fiber multi cable (sold separately).

When the unit’s power is turned on, power is supplied to the camera. 

(This setting can be changed.)

You can use the unit to input and output the video signals of various 

formats.

The unit supports HD/SD-SDI outputs, SD analog composite outputs, 

HD/SD-SDI return inputs, VBS return inputs, and prompter inputs.

Intercom calls with the camera and microphone audio output are 

possible.

The unit also comes with tally and other system interface inputs.

Connecting the AK-HRP200 ROP (sold separately) with a multi cable 

(sold separately) allows you to use the ROP to control the adjustment 

and setting of the camera and this unit.

„

„

Computer requirements

Use a host computer that satisfies the following conditions.

CPU

Intel

®

 Core

TM

2 DUO 2.4 GHz or faster, or a CPU with 

equivalent specs.

Supported 

operating systems

Microsoft

®

 Windows

®

 7 Professional SP1 32-bit

Microsoft

®

 Windows

®

 7 Professional SP1 64-bit

z

z

Use is not possible in Windows

®

 XP compatibility 

mode.

Memory

32-bit: 1 GB or more
64-bit: 2 GB or more

Web browser

Microsoft

®

 Internet Explorer

®

 8

z

z

Use is not possible with the 64-bit version of 

Internet Explorer

®

 8.

Important

If you use a computer that does not satisfy the requirements, 

problems may occur, such as screens being slow to render and 

the Web browser becoming inoperable.

„

„

Disclaimer of warranty

IN NO EVENT SHALL Panasonic Corporation BE LIABLE TO ANY 

PARTY OR ANY PERSON, EXCEPT FOR REPLACEMENT OR 

REASONABLE MAINTENANCE OF THE PRODUCT, FOR THE 

CASES, INCLUDING BUT NOT LIMITED TO BELOW:

1

  ANY DAMAGE AND LOSS, INCLUDING WITHOUT LIMITATION, 

DIRECT OR INDIRECT, SPECIAL, CONSEQUENTIAL OR 

EXEMPLARY, ARISING OUT OF OR RELATING TO THE 

PRODUCT;

2

  PERSONAL INJURY OR ANY DAMAGE CAUSED BY 

INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE 

USER;

3

  UNAUTHORIZED DISASSEMBLE, REPAIR OR MODIFICATION 

OF THE PRODUCT BY THE USER;

4

  INCONVENIENCE OR ANY LOSS ARISING WHEN IMAGES 

ARE NOT DISPLAYED, DUE TO ANY REASON OR CAUSE 

INCLUDING ANY FAILURE OR PROBLEM OF THE PRODUCT;

5

  ANY PROBLEM, CONSEQUENTIAL INCONVENIENCE, 

OR LOSS OR DAMAGE, ARISING OUT OF THE SYSTEM 

COMBINED BY THE DEVICES OF THIRD PARTY;

6

  ANY INCONVENIENCE, DAMAGES OR LOSSES RESULTING 

FROM ACCIDENTS CAUSED BY AN INADEQUATE 

INSTALLATION METHOD OR ANY FACTORS OTHER THAN A 

DEFECT IN THE PRODUCT ITSELF;

7

  LOSS OF REGISTERED DATA CAUSED BY ANY FAILURE;

8

  ANY DAMAGE OR CLAIMS DUE TO LOSS OR LEAKAGE OF 

IMAGE DATA OR SETTING DATA SAVED ON THIS UNIT OR ON 

A MEMORY CARD OR COMPUTER.

„

„

Network security

This unit also has functions which are used when it is connected to a 

network.

Using the unit when it is connected to a network may possibly give rise 

to the following.

1

  Leakage or disclosure of information transmitted via this unit

2

  Unauthorized use of this unit by a third person with malicious intent

3

  Interference or stoppage of this unit by a third person with 

malicious intent

It is your responsibility to take sufficient network security measures such 

as those described below to protect yourself against the above risks.

z

z

If this unit is used in a system with a computer connected, make 

sure that checks for and removal of computer viruses and malicious 

programs are implemented regularly.

z

z

When connecting this unit and a computer, use a crossover cable to 

connect them on a one-to-one basis connection.

Also observe the following points.

z

z

Do not install the unit in a location where the unit, cables, and other 

parts may be easily damaged.

„

„

Memory cards

Memory cards used with the unit should conform to SD or SDHC 

standards.

Be sure to use the unit to format memory cards.

Memory cards with the following capacity can be used with the unit.

SD

8 MB to 2 GB

SDHC

4 GB to 32 GB

SDXC memory cards are not supported.

For the latest information not described in the Operating Instructions, 

refer to the following website.

http://pro-av.panasonic.net/

Observe the following points when using and storing this 

unit.

z

z

Avoid high temperature and humidity.

z

z

Avoid water droplets.

z

z

Avoid static electricity.

„

„

Upgrade software

You can obtain upgrade software from Service and Support on the 

following website.

http://pro-av.panasonic.net/

For the upgrade procedure, refer to the instructions included with the 

download file.

Содержание AK-HCU200P

Страница 1: ...nstalled correctly This manual Basics is also contained as a PDF file on the CD ROM supplied with the unit Operations and Settings The Operations and Settings describes how to operate the unit and how to establish its settings The Operations and Settings is contained as a PDF file on the CD ROM supplied with the unit Adobe Reader is required to read PDF files It can be downloaded from the home pag...

Страница 2: ... Quand INDEX pdf sur le CD ROM s ouvre la liste des manuels du mode d emploi s affiche Cliquer sur le nom du document correspondant au manuel à consulter p p Adobe Reader est nécessaire pour lire les fichiers PDF Ce logiciel peut être téléchargé depuis la page d accueil d Adobe Systems ITALIANO p p Come aprire i file dei manuali di istruzioni per l uso Se inserendo il CD ROM si apre la schermata d...

Страница 3: ...connect this equipment from the AC mains disconnect the power cord plug from the AC receptacle indicates safety information WARNING This equipment must be grounded To ensure safe operation the three pin plug must be inserted only into a standard three pin power outlet which is effectively grounded through normal household wiring Extension cords used with the equipment must have three cores and be ...

Страница 4: ...ctions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat th...

Страница 5: ...ffectively earthed through the normal household wiring Extension cords used with the equipment must have three cores and be correctly wired to provide connection to the earth Wrongly wired extension cords are a major cause of fatalities The fact that the equipment operates satisfactorily does not imply that the power point is earthed or that the installation is completely safe For your safety if y...

Страница 6: ...rformance for high frequency transmission applications for analog audio signals Other connecting cables IEEE1394 USB Use double shielded cables which provide quality performance for high frequency applications as connecting cables When connecting to the DVI signal terminal use a cable with a ferrite core If your apparatus is supplied with ferrite core s they must be attached on cable s following i...

Страница 7: ...How to replace the fuse 1 Open the fuse compartment with a screwdriver 2 Replace the fuse Fuse indicates safety information Importer s name and address of pursuant to EU rules Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany Декларація про Відповідність Вимогам Технічного Регламенту Обмеження Використання деяких Небезпечних Речовин в електричному та ел...

Страница 8: ...on Abbreviations The following abbreviations are used in this manual z z Microsoft Windows 7 Professional SP1 32 64 bit is referred to as Windows 7 z z Microsoft Windows XP Professional SP3 and Microsoft Windows XP Home Edition SP3 are referred to as Windows XP z z Windows Internet Explorer 8 is referred to as Internet Explorer z z SD memory cards and SDHC memory cards are both referred to as memo...

Страница 9: ...IMAGES ARE NOT DISPLAYED DUE TO ANY REASON OR CAUSE INCLUDING ANY FAILURE OR PROBLEM OF THE PRODUCT 5 ANY PROBLEM CONSEQUENTIAL INCONVENIENCE OR LOSS OR DAMAGE ARISING OUT OF THE SYSTEM COMBINED BY THE DEVICES OF THIRD PARTY 6 ANY INCONVENIENCE DAMAGES OR LOSSES RESULTING FROM ACCIDENTS CAUSED BY AN INADEQUATE INSTALLATION METHOD OR ANY FACTORS OTHER THAN A DEFECT IN THE PRODUCT ITSELF 7 LOSS OF R...

Страница 10: ...r in a hot place where the temperature rises above 40 C 104 F because an extremely low or high temperature will adversely affect the internal parts Turn off the power before connecting or disconnecting cables Before connecting or disconnecting the cables be sure to turn the power off Avoid humidity and dust Avoid using the product in a very humid or dusty place because a lot of humidity and dust w...

Страница 11: ... objects to enter inside the unit z z Allowing water metal items food or drink or other foreign objects to enter inside the unit may cause a fire or electric shock Installation location z z This unit is designed for indoor use only z z Do not install the unit in a cold place where the temperature drops below 0 C 32 F or in a hot place where the temperature rises above 40 C 104 F z z Avoid installi...

Страница 12: ...n be controlled using the ROP z z The camera statuses are shown on the picture monitor Refer to Picture monitor PM displays of Operations and Settings When you configure the unit s settings by menu operations the menu screens are displayed on the picture monitor Refer to Menu operations of Operations and Settings z z When you configure the unit s settings by Web settings from a computer use a cros...

Страница 13: ...ixed with the intercom sound OFF The sound of PGM is not mixed with the intercom sound 8 LEVEL controls INCOM These controls are for adjusting the volume level of the sound heard through the intercom PGM This is for adjusting the volume level of the PGM sound to be mixed with the intercom sound 9 INCOM connector This connector enables calls with the intercom line of the camera Calls cannot be made...

Страница 14: ...through output connector the connector is automatically terminated at 75 Ω Connecting a cable to this connector releases 75 Ω termination When a cable is connected to the loop through output connector be sure to connect the other end of the cable to a connector Reference signal input Loop through output MIC OUT 1 connector and MIC OUT 2 connector These connectors are for outputting the analog sign...

Страница 15: ...he RTS position be sure to connect an RTS system z z When using the unit with an RTS system terminate pins 1 and 3 of the COMMUNICATION connector using a terminating resistor 200 Ω In the case of intercom signal 2 terminate pins 14 and 16 Refer to Connector pin assignment table of Operations and Settings page 38 TALLY switch MAKE V This switches the interface for the tally signal to be input to th...

Страница 16: ...s the set address and network subnet for the installation location inconsistent When the unit and computer are connected within the same subnet Are the IP addresses of the unit and computer set to a common subnet Is the Web browser set to Use a proxy server When accessing the unit in the same subnet we recommend you set the address of the unit to Don t use proxy When the unit and computer are conn...

Страница 17: ...formation bar appears Pop up blocked To see this pop up or additional options click here z z Click the information bar and then select Always Allow Pop ups from This Site The Allow pop ups from this site screen appears Click the Yes button An unnecessary status bar or scroll bar is displayed in the pop up z z Display the Security tab on the Internet Options screen of Internet Explorer and then sel...

Страница 18: ...18 Appearance Unit mm inch 424 16 11 16 29 1 1 8 29 1 1 8 482 19 400 15 3 4 13 1 2 88 3 7 16 AK HCU200P AK HCU200E 20 13 16 AK HCU200PS AK HCU200ES 29 1 1 4 ...

Страница 19: ...Reference input Black burst tri level 1 1 line 1 loop through line Microphone output 0 dBm 600 Ω 2 lines XLR 3 pin male Intercom Input 55 dBu to 10 dBu Output 100 mW max XLR 5 pin female COMMUNICATION Intercom input output 0 dBm 600 Ω RTS 4W 2 2 lines 1 2 2 PGM input 0 dBm 600 Ω 1 line Tally input red green 1 input each ROP interface RS 422 1 line 12 V output MSU interface RS 422 1 line GPI for co...

Страница 20: ... of this product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national le...