– 66 –
TURN POWER OFF
Displayed when trouble has occurred in reading data from the card or
writing data onto the card. To continue operation, turn the power off and
then back on.
E-30
stop
Error messages (continued)
Message
Error
Description
No.
Deck
operation
COMM ERROR
Displayed when the orders issued by the system control command have
not been followed even after 3 seconds have elapsed. To continue
operation, turn the power off and then back on.
E-37
stop
SYSTEM ERROR
Displayed when trouble has occurred in communication. To continue
operation, turn the power off and then back on.
E-38
stop
Error messages
Displaying the “HOURS METER” information
Turn the search dial to move the cursor (
). The description for the item where the cursor is located is shown on the
counter display.
Item
Description
No.
Counter display
Displays the deck’s serial No.
Ser
OPERATION
Displays the time that the power has been supplied in one-hour
units.
H00
0H - 99999H
LCD ON
Displays the time during which the LCD monitor has been
lighted in 1-hour increments.
H20
0H - 99999H
POWER ON
The number of times the power has been turned on is displayed
in single units.
H30
0T - 99999T
Notes:
• The resettable items in the “HOURS METER” information are reset by the shop when performing maintenance or other
work.
• The search buttons and the search dial cannot be operated while the DIAG menu is displayed.
Monitor display
No.
Message
Description
Priority
high
low
Deck operation
If “E-
” lights up in the monitor display, the contents are displayed when the DIAG-MENU is opened.
E-21 REC WARNING
Displayed when trouble has occurred in the video or audio during
recording. To continue operation, turn the power off and then back
on.
stop
E-25 IRREGULAR CLIP
Displayed when there is an irregular clip. Recording can be continued
even while this message is displayed, but the clip should be fixed if,
for example, it is necessary to regenerate the time code.
Fix the card by performing the thumbnail operations.
operation
continues
E-29 BATTERY EMPTY
Displayed when a drop in the voltage of the internal clock's backup
battery has been detected while the power is on.
Replace the internal battery.
operation
continues
E-10 FAN STOP
Displayed when the fan motor has stopped.
Check the fan motor for foreign matter or objects.
operation
continues