(*) The counter display flashes to provide a warning.
ERROR MESSAGES
70
E-64
E-65
E-66
E-67
E-68
E-69
E-70
E-71
E-72
E-73
E-BA
STOP
STOP
STOP
STOP
STOP
STOP
Forced POWER OFF
Forced POWER OFF
Forced POWER OFF
Forced POWER OFF
Forced POWER OFF (*)
The take-up reel motor speed is abnormally high.
Abnormal tension has been detected.
At the tape start or end, the short FF or REW operation does not stop even after 7
or more seconds.
A check sum error was detected in the serial data communication between the
syscon and servo.
In serial data communication between the syscon and servo, the data was fixed at
low or high and the absence of data was detected.
A communication error was detected in the serial data between the syscon and
servo when the power was turned on.
About an hour has elapsed after the fan motor stopped. The VTR forcibly turns off
its power.
The heat sensor was activated and an abnormally high temperature inside the
VTR was detected.
Trouble in the solenoid drive circuitry was detected.
Trouble in the cleaning solenoid drive circuitry was detected.
The input supply voltage dropped below the undercut voltage.
Error No.
Details of error
VTR operation