INTERFACE
Item
Setting
Description of setting
No.
Item
No.
Item
200
ID SEL
0000
OTHER
0001
DVCPRO
™ ™
201
LOCAL ENA
0000
DIS
0001
ST&EJ
™ ™
202
OPTION MODE
0000
EDL
0001
AMU1
0002
AMU2
™
0003
AMU3
203
BAUD RATE
0000
1200
0001
2400
0002
4800
0003
9600
™
0004
19200
204
DATA LENGTH
0000
7
0001
8
™
205
STOP BIT
0000
1
0001
2
™
206
PARITY
0000
NON
0001
ODD
™
0002
EVEN
207
FLOW
0000
NONE
CONTROL
0001
RTSCTS
™
208
EDL FORMAT
0000
AGA850
0001
CMX340
™
The underlined number and item are the factory settings.
DETAILED DESCRIPTION OF SET-UP MENUS
26
This selects the ID information which is to be returned to the controller.
0: 20 25H
1: The ID (F0 33H) unique to DVCPRO is returned.
This selects the switches which can be operated on the front panel when the
REMOTE/LOCAL switch is at REMOTE.
0: None of the switches or buttons can be operated.
1: Only the STOP (ALL STOP) and EJECT buttons can be operated.
This sets the EDL connector (9P) mode.
0: For dumping/loading EDL data.
1: The audio memory unit is used under the audio dubbing specifications.
2: The audio memory unit is used under the audio channel 2 fade specifications.
3: The audio memory unit is used under the audio channel 1 fade specifications.
This sets the baud rate when EDL is set for set-up menu item No.202
(OPTION MODE).
This sets the data length when EDL is set for set-up menu item No.202
(OPTION MODE).
This sets the stop bit when EDL is set for set-up menu item No.202 (OPTION
MODE).
This sets the parity when EDL is set for set-up menu item No.202 (OPTION-
MODE).
This enables or disables the flow control for the EDL data communication.
0: Flow control using RTS/CTS is disabled.
1: Flow control using RTS/CTS is enabled.
This sets the format with which EDL data is to be dumped.
0: Format common with Matsushita’s AG-A850.
1: Format common with the CMX340 editing system.
V
V
T
T
R
R
1
2