OPERATION
Item
Setting
Description of setting
No.
Item
No.
Item
108
HUMID
0000
OFF
OPE
0001
ON
™
109
SEARCH
0000
DIAL
™
ENA
0001
KEY
110
AUTO REW
0000
OFF
™ ™
0001
ON
111
ALL STOP SEL
0000
STOP
™
0001
STILL
The underlined number and item are the factory settings.
25
V
V
T
T
R
R
1
2
Detailed
description
of
set-up
menus
DETAILED DESCRIPTION OF SET-UP MENUS
This selects whether condensation is to be ignored when it has formed and
operation is to be continued.
0: Operation is disabled.
1: Operation is enabled. Although operation is still possible even when con-
densation has formed, the unit’s operation cannot be guaranteed.
<Note>
Since the tape may be damaged or other trouble may occur when “1:
Operation is enabled” is selected, “0: Operation is disabled” is normally
selected.
This selects whether the direct search operation is to be performed.
DIAL: Direct search mode
KEY: No direct search mode (The search dial is operable in the STILL mode
only.)
This selects whether the tape is automatically rewound to the beginning when
the end of the tape is detected in the PLAY, REC, or SHTL modes.
0: Transport stops at the end of the tape.
1: The tape is automatically rewound to the beginning.
This is used to select the mode to which the unit is to be set when the ALL
STOP button is pressed.
0: The unit is set to the STOP mode.
1: The unit is set to the still-picutre mode (SHTL +0.0, JOG STILL).