154
For Long and Trouble-Free Operation: Error Messages
If “E- * * ” Iights in the monitor display, hold down the SHIFT button and press the MENU button to open the DIAG-MENU and
read the warning information.
◆
NOTE:
*1 This warning appears only during recording. Then the audio is recorded mute.
*2 This warning appears only during recording. The internally generated time code is recorded.
INVALID
Appears when there are already 100 text memos and no more memos can be
added.
Operation
continues
INVALID
BUSY
Displayed while clip information is being read or when clip configuration has
changed. No operations can be performed while this display is on the screen.
[Meaning]
• A card has been inserted or removed.
• Updating is in progress
• Recording post processing is in progress
• Other causes
Operation
continues
BUSY
INT SG
Displayed for the first two seconds when the REC button is pressed to enter the
EE mode and the INPUT SELECT VIDEO button or the INPUT SELECT AUDIO
button is set to SG.
Operation
continues
INT SG
NO INPUT
Displayed for the first two seconds when the REC button is pressed to enter the
EE mode and the INPUT SELECT button is set to a connector with no output
except for analog audio signals.
Operation
continues
NO INPUT
TEXT MEMO
Displayed for two seconds when a text memo is added.
Operation
continues
TEXT MEMO
MARK ON/OFF
Displayed for two seconds when a shot mark is added or deleted.
Operation
continues
MARK ON /
MARK OFF
WARNING information
Display
Description
Deck operation
No
Character code
04
UNKNOWN SIG
Displayed when a signal input from the 1394 interface is not a DVCPRO or DV format
signal.
Recording is
disabled
10
FAN STOP
Displayed when the fan motor stops.
Operation
continues
11
NOT 1× 25M SIG
Displayed when a signal input from the 1394 interface is not a DVCPRO (25 Mbps) 1×
normal speed transfer signal.
Recording is
disabled
12
NOT 1× 50M SIG
Displayed when a signal input from the 1394 interface is not a DVCPRO50 (50 Mbps) 1×
normal speed transfer signal.
Recording is
disabled
14
NO MATCH SIG
Displayed when signal input via the 1394 interface differs from the system format set on
this unit.
Recording is
disabled
15
NOT 1× DV SIG
Displayed when a signal input from the 1394 interface is not a DV (25 Mbps) 1× normal
speed transfer signal.
Recording is
disabled
16
INVALID VIDEO SIG
Displayed when the compressed video data of a signal input from the 1394 interface is
irregular.
Recording is
disabled
17
INVALID AUDIO SIG
Displayed when the audio data of a signal input from the 1394 interface is irregular.
Operation
continues
*1
18
INVALID TC SIG
Displayed when the time code data of a signal input from the 1394 interface is irregular. Operation
continues
*2
21
REC WARNING
Displayed when a video or audio error occurs during recording.
To continue operation, turn the power off and then back on again.
STOP
26
CARD
ERROR<******>
Displayed when data was corrupted due to a P2 card error during recording.
This error is displayed after recording ends and until the start of the next operation. This
error is not displayed during playback. (* indicates the slot number where the error
occurred.)
Replace the P2 card in the slot where the error occurred.
STOP
Monitor display
Description
Deck operation