114
Chapter 8 Menu Description Tables
(continued)
<Note>
The remaining battery capacity for digital batteries is
displayed as % inside the viewfinder (PRO14/TRIM14/
HYTRON50/HYTRON100/HYTRON120/DIONIC90/
DIONIC160/NP-L50/ENDURA50/ENDURA80).
The BATT NEAR END alarm, however, is triggered
according to the setting on the <BATTERY SETTING1>
screen, regardless of the % indication.
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Data Saved
Adjustable
Range
Remarks
DIONIC90
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
13.6
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
DIONIC160
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
13.3
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
HP-90L
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
12.8
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
BP-H120
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
11.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
NP-L50
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
13.3
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
Items/
Data Saved
Adjustable
Range
Remarks
ENDURA50
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
13.1
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
ENDURA80
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
13.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
BP-L60/90
_
•
Enable selection under BATTERY
SELECT.
_
:
Enable selection.
• :Disable selection.
MANUAL
AUTO
Select auto or manual to set the NEAR
END voltage.
MANUAL:
Set voltage manually.
AUTO:
Set voltage automatically.
11.0
:
11.2
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in
0.1 V steps.
– C U F –
#,52%''PINKUJDQQMࡍࠫ㧞㧜㧜㧡ᐕ㧤㧝㧢ᣣޓἫᦐᣣޓඦᓟ㧞ᤨ㧡㧥ಽ