-5-
13. Recording Output Connector (REC OUT)
This connector supplies the recording signal for the
time lapse VTR.
Caution:
In MULTIPLEX mode, the unit adds codes to
video signals during vertical blanking while they
are recorded on the VTR. This is the reason
why video signals with a certain code are not
recordable during vertical blanking.
14. Monitor Output Connector (MONITOR OUT)
This connector supplies a composite video signal
for monitoring. Sequential picture, time lapse VTR
playback pictures and the menus can be displayed
on a connected monitor.
15. Camera Switching Signal Input Connector
(CAMERA SW IN)
The camera switching signal from the time lapse
VTR is supplied to this connector. This connector
works only when the MULTIPLEX mode is selected.
Note:
When REC MODE is set to T/L but no camera
switching signal is supplied, time lapse record-
ing will not work properly.
16. ALARM/REMOTE Connector
This connector is used for remote controlling. You
can control the following functions:
• Alarm Output
• Recover Input
• MULTISCREEN
• SEQ
• Receiving the alarm input signal at the camera
site, or the remote input signal for the camera
selection buttons.
17. Ground Terminal
18. Power Cord