4
Features
Recording and playback in 24- and 40-hour time
modes with the NV-T160 tape
In addition to the 8-hour time mode, recording and
playback can be performed in the time lapse modes
(24- and 40-hour modes).
Excellently defined still-picture images
More clearly defined still picture images can be pro-
duced during playback in color and black-and-white
modes thanks to the horizontal resolution of more than
300 lines.
Full line-up of recording functions
Included in the wide range of recording functions are
restoration-of-power-after-failure recording, recording
every day and by the days of the week using the
internal timer, external timer recording, alarm recording,
emergency recording and repeat recording.
Playback functions
Among the convenient playback functions are the
recording review function for immediate viewing of
recorded material, the handy search function for
locating images promptly, and the forward/reverse field
advance and still-picture functions for careful viewing of
particular scenes.
Repeat recording count display
The number of times a recording is to be repeated can
be indicated on the counter display.
Jog/shuttle
A jog or shuttle function for quickly locating playback
sections using the search dial is incorporated.
Auto tracking function
The tracking can be automatically adjusted by pressing
the “–” and “+” tracking buttons together.
Built-in time/date generator
This unit comes with a built-in microprocessor with a
calendar function for displaying the time on the display
or TV monitor and for controlling the time of the internal
timer.
Recording lock function
A double recording mode lock function is provided for
safeguarding against operational errors during recording.
Connection to sequential switcher
Easy connection to a sequential switcher is possible
once the unit has been connected to the video input and
camera SW connectors.
Hour meter
The unit contains an hour meter which provides useful
information for maintenance and inspections.
Remote control
The unit can be operated from a distance of about 16 ft.
if the AG-A11 remote controller, available as an optional
accessory, is connected.
Regular Maintenance Service Recommendation
Although this unit is designed to withstand long-term use, the items listed below should be inspected regularly so that
the unit is kept in perfect working order. Use the hour meter to know when to conduct the inspections.
The VTR is a piece of precision-made equipment and, as such, it is recommended that the user enter into a
maintenance and inspection agreement to keep the unit operating free of trouble or failures. For further details,
please consult with your dealer.
Service life inspection
Cleaning
Cumulative operation time
(hours)
Inspection item
Transport system cleaning
Audio heads
Video heads
Cylinder unit
(24-/40-hour mode use)
500
1000
1500
2000
2500
3000
3500
4000
8000
12000
The above table merely serves to lay down general guidelines for the inspection of typical parts involved in regular
inspections. The timing of the inspections needs to be adjusted according to the VTR’s operating environment.