26
4-7 Contents of Menu Switches
4 ON-SCREEN/MENU SWITCHES
[ ]: Factory setting • The lower section in the items and set values columns shows what’s on the VCR’s display.
Screens
Items
Set values
Function
AL/SENSOR
[OFF]
IN
ON
OFF
ON
Selects whether or not the buzzer sounds during alarm or sensor
recording.
OFF: The buzzer does not sound.
ON: The buzzer sounds.
BU 22 2
BU 22 3
ERR WARN
[OFF]
ON
OFF
ON
Sets whether or not the buzzer sounds when a warning occurs.
OFF: The buzzer does not sound.
ON: The buzzer sounds. When the warning is released, the buzzer
sound stops.
IN/OUT
CAMERA SW
[OFF]
1 FIELD
2 FIELD
OFF
1FRD
2FRD
Sets the camera switching signal output interval.
OFF:
No camera switching signal is output.
1 FIELD: Set to this position to switch cameras every 1 field. (However
1 frame when on 2H or 6H.)
2 FIELD: Set to this position to switch cameras every two fields (1
frame).
Sets whether or not the buzzer sounds when the tape ends in the Record mode.
OFF: The buzzer does not sound.
ON: The buzzer sounds when the tape ends during recording. Also, the buzzer
sounds when the tape reel counter value set with the menu switch <CNT
TAPE END> on the SRI/EXT MODE screen is reached.
When the mode is changed by pressing the [REW] button, [EJECT]
button or [OPERATE] button, the buzzer sound stops.
BUZZER
TAPE END
[OFF]
ON
OFF
ON
BU 22 1
OFF
STOP
DURATION
5 SEC
10 SEC
15 SEC
30 SEC
60 SEC
120 SEC
[180 SEC]
CONTINUE
MANUAL
5
..
.
180
CONT
nANU
ALARM/
SENSOR
MODE
Selects the recording duration for alarm or sensor recording.
5 — 180 SEC: Alarm or sensor recording is performed for the specified
time (5 sec. to 180 sec.)
CONTINUE: Alarm or sensor recording continues to the end of the tape.
MANUAL:
Alarm or sensor recording continues for as long as alarm
signals are input. Set to this position when specifying the
alarm recording time with a switcher.
*To ensure accurate alarm search and alarm scan operation,
be sure to set the recording time to 5 seconds or more.
TAPE END
[OFF]
MODE
STOP
Selects whether or not the Stop mode is forcibly engaged when the tape ends
even if there is an alarm or sensor recording.
OFF: The forced Stop mode is not engaged.
• When the tape ends, the mode set with the menu switch <AUTO
REW> or <REPEAT REC> on the <VTR MODE> screen is engaged.
STOP: The Forced Stop mode is engaged.
AL SE 3
(VCR's display)
AL SE 4
iO
1
REC T-MODE
[2H]
6H
L12H
L18H
L24H
24H
48H
NORMAL
2H
6H
L12H
L18H
L24H
24H
48H
NORn
Selects the recording mode for alarm or sensor recording.
(Refer to page 28.)