117
Setup menu list
C
h
ap
te
r 7 M
en
u O
p
er
at
io
n
s
BATTERY SETUP screen
Item
Description of settings (Items in bold are factory settings.)
EXT DC IN SEL
Selects external DC power supply type.
●
AC ADAPTER: AC adapter
●
BATTERY: battery
BATTERY SELECT
Selects battery type.
●
PROPAC14, TRIMPAC14, HYTRON50, HYTRON140,
DIONIC90
, DIONIC140, NP-L7, ENDURA7,
ENDURA10, ENDURA-D, PAG L95, BP-GL65/95, NICD14, TYPE A, TYPE B
BATTERY MODE
Near end setting
●
AUTO: Automatically sets one of the following battery types.
PROPAC14, TRIMPAC14, HYTRON50, HYTRON140, DIONIC90, DIONIC140, NP-L7, ENDURA7,
ENDURA10, ENDURA-D, PAG L95, BP-GL65/95
●
MANUAL: Manually enter near end voltage for battery types other than those listed above.
PROPAC14 NEAR
Sets near end voltage for PROPAC14
• Adjustable in 0.1 V units.
TRIMPAC14NEAR
Sets near end voltage for TRIMPAC14
• Adjustable in 0.1 V units.
HYTRON50 NEAR
Sets near end voltage for HYTRON50
• Adjustable in 0.1 V units.
HYTRON140 NEAR
Sets near end voltage for HYTRON140
• Adjustable in 0.1 V units.
DIONIC90 NEAR
Sets near end voltage for DIONIC90
• Adjustable in 0.1 V units.
DIONIC160 NEAR
Sets near end voltage for DIONIC160
• Adjustable in 0.1 V units.
NP-L7 NEAR
Sets near end voltage for NP-L7
• Adjustable in 0.1 V units.
ENDURA7 NEAR
Sets near end voltage for ENDURA7
• Adjustable in 0.1 V units.
ENDURA10 NEAR
Sets near end voltage for ENDURA10
• Adjustable in 0.1 V units.
ENDURA-D NEAR
Sets near end voltage for ENDURA-D
• Adjustable in 0.1 V units.
PAGL95 NEAR
Sets near end voltage for PAG L95
• Adjustable in 0.1 V units.
BP-L65/95 NEAR
Sets near end voltage for BP-GL65/95
• Adjustable in 0.1 V units.
NICD14 NEAR
Sets near end voltage for NICD14
• Adjustable in 0.1 V units.
NICD14 END
Sets end voltage for NICD14
• Adjustable in 0.1 V units.
TYPEA FULL
Sets full voltage for TYPE A
• Adjustable in 0.1 V units.
TYPEA NEAR
Sets near end voltage for TYPE A
• Adjustable in 0.1 V units.
TYPEA END
Sets end voltage for TYPE A
• Adjustable in 0.1 V units.
TYPEB FULL
Sets full voltage for TYPE B
• Adjustable in 0.1 V units.
TYPEB NEAR
Sets near end voltage for TYPE B
• Adjustable in 0.1 V units.
TYPEB END
Sets end voltage for TYPE B
• Adjustable in 0.1 V units.
NEAR END CANCEL
Selects whether to cancel battery near end warning or not.
Содержание AG-HPX500
Страница 3: ... 3 ...
Страница 4: ... 4 ...
Страница 6: ... 6 Read this first ...
Страница 7: ... 7 ...
Страница 8: ...MHNK250 0123456S7P ...
Страница 117: ...MPL 17 LCD PARTS ASSEMBLY 101 101 101 1 6 7 8 9 E12 101 2 3 4 5 ...
Страница 153: ...Panasonic Broadcast AG HPX500 Menu Information ...
Страница 185: ...MPL 17 LCD PARTS ASSEMBLY 101 101 101 1 6 7 8 9 E12 101 2 3 4 5 ...