Table 6: XMT1000 modbus register map - revision 4.19
Reg #
in hex
Access
level
Register ID
Description
Units
RO/
RW
Size in
bytes
Format
748
N/A
eSystem_OPT_Startup_Err
Option startup error
Unitless
RO
4
INT32
74A
N/A
eSystem_comm_Err
Comm error
Unitless
RO
4
INT32
74C
N/A
eSystem_comm_TryNum
Comm try times
Unitless
RO
4
INT32
74E
N/A
eSystem_comm_FailNum
Comm fail times
Unitless
RO
4
INT32
750
N/A
eSystem_comm_
wrongNum
Comm data wrong times
Unitless
RO
4
INT32
752
N/A
eSystem_Cmd_State
System command state
Unitless
RO
4
INT32
System real RO
Display real RW
800
Display int RW
900
900
Operator
eDisplay_Language
Display language
Unitless
RW
4
INT32
902
Viewer
eDisplay_Var1_value
Display variable_
1 register address
Unitless
RW
4
INT32
904
Viewer
eDisplay_Var1_Unit
Display variable_
1 unit code address
Unitless
RW
4
INT32
906
Viewer
eDisplay_Var2_value
Display variable_
2 register address
Unitless
RW
4
INT32
908
Viewer
eDisplay_Var2_Unit
Display variable_
2 unit code address
Unitless
RW
4
INT32
90A
Viewer
eDisplay_Tot1_Value
Display totalizer_
1 register address
Unitless
RW
4
INT32
90C
Viewer
eDisplay_Tot1_Unit
Display totalizer_
1 unit code address
Unitless
RW
4
INT32
90E
Viewer
eDisplay_Tot2_Value
Display totalizer_
2 register address
Unitless
RW
4
INT32
910
Viewer
eDisplay_Tot2_Unit
Display totalizer_
2 unit code address
Unitless
RW
4
INT32
30
Содержание PanaFlow XMT1000