6.3 Meter body and transducer
Pressure rating
Up to maximum allowable flange operating pressure at
temperature, per ASME B16.5
Temperature range
WT Transducers:- 40 to 175°C (-40 to 347°F)
BWT Transducers: -40 to 100°C (-40 to 212°F)
-40 to 250°C (-40 to 482°F)
Temperature rating of -20°C if used with carbon steel meter
body
Transducer material
316L Stainless steel (buffers)
Meter Body materials
Carbon steel
Stainless steel (316/316L)
Certification
Electronics/Transducers: Explosion-proof Class I, Division 1,
Groups B,C&D
ATEX Flameproof II 2 G Ex d IIC T6
IECEx Flameproof II 2 G Ex d IIC T6 (BWT only)
Flow Cell: NACE MR0175 and MR0103, PED 2014/68/EU
Dimensions
Refer to drawings 712-2122 to 712-2125
Drawing
Description
712-2122
General arrangement drawing, PanaFlow LZ,
6” and 3”, 1 path, 2 traverse, tilted diameter
712-2123
General arrangement drawing, PanaFlow LZ,
4” to 24”, 1 path, 1 traverse, tilted diameter
712-2124
General arrangement drawing, PanaFlow LZ,
3” and 4”, 2 path, 1 traverse, tilted diameter
712-2125
General arrangement drawing, PanaFlow LZ,
6” to 24”, 2 path, 1 traverse, mid-radius