12/1/99
1-14
Programming Site Data
The SYSTM Sub-Menu
(cont.)
Note:
The option bar above shows English units. If Metric units are
specified in the
GLOBL
menu, these will appear instead.
The abbreviations and definitions of all the available volumetric and
totalizer units are shown in Table 1-3 on page 1-13. The choices
shown on the option bar above are determined by the selection made
at the
SYSTEM UNITS
prompt screen.
When the previous selection has been made, the meter will exit the
SYSTM
sub-menu and return to the
Channel PROGRAM
prompt. To
leave the User Program, press
[EXIT]
twice. If changes have been
made in any of the sub-menus, the following screen appears:
Note:
See the
SAVE
sub-menu section on page 1-62 for more
information on this function.
Chan 1 SYSTM
Press
[F1]-[F4]
to select the
desired units for the totalized
mass flow display
.
MDOT DECIMAL DIGITS
current setting appears here
MASS (TOTALIZER)
current setting appears here
LB
KLB
MMLB
TONS
Chan 1 SYSTM
Press
[F1]-[F4]
to select the
desired number of digits to the
right of the decimal point in the
totalized mass flow display.
MASS (TOTALIZER)
current setting appears here
MASS DECIMAL DIGITS
current setting appears here
0
1
2
3
PROGRAM Start
At the User Program screen
shown, press
[F1]
to return to
measurement mode without
saving the file or press
[F2]
to
enter the
SAVE
sub-menu.
Do you want to SAVE
current selection appears here
No
Yes
Содержание GF868
Страница 1: ...Model GF868 Programming Manual Two Channel...
Страница 6: ...Chapter 1...
Страница 71: ...Chapter 2...
Страница 92: ...Chapter 3...
Страница 113: ...Chapter 4...
Страница 131: ...Chapter 5...
Страница 132: ...Clearing Data Introduction 5 1 The TOTAL Sub Menu 5 2 The SITE Sub Menu 5 3 The LOG Sub Menu 5 4...
Страница 138: ...12 1 99 5 6 Clearing Data...
Страница 139: ...Chapter 6...
Страница 150: ...Appendix A...
Страница 159: ...Appendix B...
Страница 160: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2...