12/1/99
1-10
Programming Site Data
The ACTIV Sub-Menu
(cont.)
If Skan is selected at the next prompt, the instrument uses this
technique exclusively. However, if S/M is selected, the meter uses
Skan to find the acoustic signal and then tries to use the Measure
technique for a more precise measurement.
Note:
To change the
Skan
and
Measure
parameters, see the
SIGNL
sub-menu section on page 1-23.
To leave the User Program and return to measurement mode, press
[EXIT]
twice on the keypad. If changes have been made in any of the
sub-menus, the following screen appears:
Note:
See the
SAVE
sub-menu section of this chapter for more
information on this function.
The SYSTM Sub-Menu
While following the programming instructions, refer to the menu map
in Figure A-1 on page A-1 in Appendix A, Menu Maps. To enter this
sub-menu, press
[F2]
at the
Channel PROGRAM
prompt.
IMPORTANT:
Do not confuse this
SYSTM
sub-menu, which is used
to enter channel-specific information, with the
SYSTM
sub-menu of the
GLOBL
menu, which is used
to enter information applicable to both channels.
PROGRAM Start
At the User Program screen
shown, press
[F1]
to return to
measurement mode without
saving the data or press
[F2]
to
enter the
SAVE
sub-menu.
Do you want to SAVE
previous selection appears here
No
Yes
Chan 1 SYSTM
É
Enter a channel label of up to 9
characters and press the
[ENT]
key. (When in measurement
mode, the channel label will
appear on the locator bar.)
Channel PROGRAM
system
CHANNEL LABEL
current label appears here
Chan 1 SYSTM
É
Enter a channel message of up to
21 characters. Use this screen to
enter a brief description of the
channel. When done, press the
[ENT]
key.
CHANNEL LABEL
current label appears here
CHANNEL MESSAGE
current message appears here
Содержание GF868
Страница 1: ...Model GF868 Programming Manual Two Channel...
Страница 6: ...Chapter 1...
Страница 71: ...Chapter 2...
Страница 92: ...Chapter 3...
Страница 113: ...Chapter 4...
Страница 131: ...Chapter 5...
Страница 132: ...Clearing Data Introduction 5 1 The TOTAL Sub Menu 5 2 The SITE Sub Menu 5 3 The LOG Sub Menu 5 4...
Страница 138: ...12 1 99 5 6 Clearing Data...
Страница 139: ...Chapter 6...
Страница 150: ...Appendix A...
Страница 159: ...Appendix B...
Страница 160: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2...