Chapter 1. Programming Site Data
18
DigitalFlow™ GS868 Programming Manual (2-Channel)
Both the upstream and downstream transducers transmit ultrasonic pulses in bursts, which consist of a series of
transmit pulses.
XMIT SAMPLE SIZE
determines how many bursts are sent in one direction before sending in the other
direction. The default value for this parameter is 8 and values of 2, 4, 8, 16 and 32 are acceptable.
13.
Press
[ENT]
to accept the current
M>S_Switch
value or enter a new value and press
[ENT]
.
IMPORTANT:
Consult the factory before performing this step.
If the burst mode is set to Skan/Measure (S/M), the meter switches from Skan to Measure Mode when Delta T is less
than the
M>S_Switch
value.
DO NOT
change this value unless advised to do so by the factory. The default value for
this parameter is 50
sec and values from 0 to 250
sec are acceptable.
14.
Press
[ENT]
to accept the current
# shifts
value or enter a new value and press
[ENT]
.
The number of shifts corresponds to the actual number of transmits per cycle (number of signals added together in
one direction to produce an averaged signal for one interrogation of the fluid) and need only be changed if the
environment is very noisy or the acoustic signal is weak. The default value for this parameter is 3 and values from 0 to
10 are acceptable.
15.
Press
[ENT]
to accept the current
A Divisor
value or enter a new value and press
[ENT]
.
A Divisor
is used in the calculation of the Measure Mode integrated threshold level and is not normally changed. The
default value for this parameter is 2.5 and values from 0.1 to 10 are acceptable.
16.
Press
[ENT]
to accept the current
# Transmit Pulses
value or enter a new value and press
[ENT]
.
IMPORTANT:
Consult the factory before performing this step.
# Transmit Pulses
specifies the number of pulses in a burst. The default value for this parameter is 4 and values from
1 to 16 are acceptable. For difficult conditions (i.e., long paths, high velocity or high temperature), settings as high as
16 may be necessary.
17.
Press
[ENT]
to accept the current
T WINDOW (Cycles)
value or enter a new value and press
[ENT]
.
IMPORTANT:
Consult the factory before performing this step.
Normally, the Model GS868 calculates the size of the transmit window based on pipe size and fluid sound speed.
However, for special diagnostic purposes, it may sometimes be necessary to reset the window size. The default value
for this parameter is 0 and values from 0 to 1000 are acceptable.
18.
Press
[ENT]
to accept the current
R WINDOW (cycles)
value or enter a new value and press
[ENT]
.
IMPORTANT:
Consult the factory before performing this step.
Normally, the Model GS868 calculates the size of the receive window based on pipe size and fluid sound speed.
However, for special diagnostic purposes, it may sometimes be necessary to reset the window size. The default value
for this parameter is 10 and values from 10 to 128 are acceptable.
After completing these steps, the program returns to the
SETUP window.
Содержание DigitalFlow GS868
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 10: ...Contents viii DigitalFlow GS868 Programming Manual 2 Channel...
Страница 58: ...Chapter 2 Displaying Data 48 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 91: ...DigitalFlow GS868 Programming Manual 2 Channel 81 Appendix A Menu Maps...
Страница 92: ...82 DigitalFlow GS868 Programming Manual 2 Channel...
Страница 100: ...DigitalFlow GS868 Programming Manual 2 Channel 90...
Страница 104: ...94 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 122: ...112 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 136: ...126 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 140: ...Index 4 DigitalFlow GS868 Programming Manual 2 Channel...
Страница 144: ...Chapter 2 DigitalFlow GS868 Programming Manual 2 Channel...
Страница 145: ......