Panametrics Infrastructure Products Used in Hazardous
Locations
Installation and operation manuals in their complete forms, along with product specific certification and safety
statement sheets are included on the CD provided with the product documentation shipped with each instrument.
Please read and follow all provided manufacturer’s instructions prior to installation and the application of power to
your equipment. Always observe the following:
•
Field wiring shall be rated at least 10°C above rated ambient.
•
Connecting cables shall be mounted securely and protected from mechanical damage, pulling and twisting.
•
Cable entry thread types are identified on the equipment label.
•
Cable glands of an approved flameproof design are required for
Ex d
rated equipment. These must be installed
according to the manufacturer’s instructions. Where the cable glands are provided by Panametrics, the
manufacturer’s instructions, as supplied to Panametrics, will be included in the documentation.
•
Unused cable entries must be sealed using a suitably certified threaded plug.
•
Modifications to any flameproof enclosure are not permitted.
•
The apparatus must be de-energized before opening, servicing and conducting any routine maintenance.
•
Installation shall be in accordance with the installation instructions and the National Electrical Code
®
ANSI/NFPA
70, the Canadian Electrical Code C22.1, or IEC/EN 60079-14, as applicable.
•
The product contains no exposed parts which produce surface temperature infrared, electromagnetic ionizing,
or non-electrical dangers.
•
The product must not be subjected to mechanical or thermal stresses in excess of those permitted in the
certification documentation and the instruction manual.
•
The product cannot be repaired by the user. It must be replaced by an equivalent certified product. Repairs
should only be carried out by the manufacturer or by an approved repairer.
•
Only trained, competent personnel may install, operate and maintain the equipment.
•
The product is an electrical apparatus and must be installed in the hazardous area in accordance with the
requirements of the
EC Type Examination Certificate. The installation must be carried out in accordance with all
the appropriate international, national and local standard codes and practices and site regulations for
flameproof apparatus and in accordance with the instructions contained in the manual. Access to the circuitry
must not be made during operation.
Содержание DigitalFlow GS868
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 10: ...Contents viii DigitalFlow GS868 Programming Manual 2 Channel...
Страница 58: ...Chapter 2 Displaying Data 48 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 91: ...DigitalFlow GS868 Programming Manual 2 Channel 81 Appendix A Menu Maps...
Страница 92: ...82 DigitalFlow GS868 Programming Manual 2 Channel...
Страница 100: ...DigitalFlow GS868 Programming Manual 2 Channel 90...
Страница 104: ...94 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 122: ...112 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 136: ...126 DigitalFlow GS868 Programming Manual 2 Channel no content intended for this page...
Страница 140: ...Index 4 DigitalFlow GS868 Programming Manual 2 Channel...
Страница 144: ...Chapter 2 DigitalFlow GS868 Programming Manual 2 Channel...
Страница 145: ......