background image

2

INTRODUCTION

A backlit analog voltmeter indicates the AC
line voltage coming into your system.

A combination ON/OFF/Dimmer switch
controls the meter lighting.

An always-on, convenience outlet on the
front panel for temporary AC connections.

Sequential start-up and shut-down of your
system using an A/V receiver (or other
component) and the 12VDC trigger input.

12V Trigger Output with selectable output
delay.

RS232 Control for interfacing to automation
systems.

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

Your Audio/Video components are constantly
being bombarded by electromagnetic interfer-
ence (EMI) and radio frequency interference
(RFI) through their power cords.  This contami-
nated power can affect A/V equipment and will
degrade the overall performance of your entire
system.  Common symptoms of contaminated
power include pops, hisses, hums, visual arti-
facts, etc.   Most power filtering devices will
remove some of this interference but don’t 
provide a real solution to the problem.

The MAX

®

5410 Sophisticated Filtration

System is a Real Solution! 

Filtered Outlet Banks:

The primary noise filtration system features
cascaded banks of filter circuits that supply
power to the Always-On and Switched outlets.
The filtration circuitry has been specifically
designed to filter out all forms of electromag-
netic and radio frequency noise in both com-
mon and normal modes.  There are four banks
of outlets with two outlets per bank.  Cross-
contamination between the outlet banks is also
eliminated with this design.

Outlet Banks 1 and 2 are always on, providing
continuous power to those components with
programmable memory settings.  Banks 3 and
4 can be set to either always on or switched.  A
rear panel slide-switch provides the option of a
10 second shutdown delay if these outlets are
configured as Switched.

As you read through the rest of this manual,
you’ll discover many more unique features.  
As audiophiles, we care about the quality of
your listening and/or viewing experience.  
Our goal is to:

• Provide clean pure power

• Protect your investment

• Enhance the pleasure you get from you’re

A/V system

Thank you for choosing Panamax for your
power quality needs.  Please finish reading
the instructions, install your MAX

®

5410 and

enjoy the full potential of your entertainment
system.

High-Current Outlet Bank:

The unique power requirements of current
hungry components such as amplifiers and
powered subwoofers are also addressed.
These components can rapidly draw large
amounts of current to replenish their power
supply capacitors after thunderous bass notes.
Line conditioners that utilize coils (inductors)
in series with the AC power line can “choke”
off this large inrush current, thereby reducing
the amplifiers’ ability to operate at peak 
performance levels, resulting in a flat, dead
sound.  The MAX

®

5410 high-current outlets

are fed by noise filtration circuitry that does
not utilize coils and provides full, unimpeded
power for your amplifiers and powered sub-
woofers.

Other Features Enhance the
Functionality:

Although the MAX

®

5410 functionality revolves

around noise filtration and power protection,
many other exciting features enhance the overall
entertainment experience, including:

Содержание MAX 5410 Pro

Страница 1: ...MAX 5410 Pro Series Owner s Manual 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Страница 2: ...ed noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for each piece of equipment in your entertainment...

Страница 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Страница 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Страница 5: ...3 CONNECTION DIAGRAMS Basic Signal Line Connections Typical AC Power RS232 and 12V Trigger Connections USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 STEP 1 STEP 2...

Страница 6: ...witch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satellite Coax Jacks Two pairs of gold plated F Connectors optimized for Satellite TV signal line protec...

Страница 7: ...n button is pressed quickly 2 sec SWITCHED and HIGH CURRENT outlets turn off for 10 seconds then turn back on in a sequence per delay settings The purpose is to cycle power to equipment that locks up...

Страница 8: ...dark room LEDs light emitting diodes are used as the light source in order to provide durability and long life The Meter Light dimmer controls the brightness level or turns the lighting off altogethe...

Страница 9: ...is comprehensive network of filters while banks 1 and 3 benefit from additional Balanced L filters Outlet Banks 1 and 2 contains four switched outlets that will turn your connected equipment ON or OFF...

Страница 10: ...ignal will initiate the startup or shutdown sequence of the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may als...

Страница 11: ...cy range of 950Mhz to 2 2Ghz The clamping level of the MAX 5410 s satellite protection circuitry is 27 volts just 3 volts above the maximum operating voltage The circuitry is shielded to prevent inter...

Страница 12: ...e following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage c...

Страница 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Страница 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Страница 15: ...t the status of the outlet banks PS responds with a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switch...

Страница 16: ...INS5410 REV A USA Canada 800 472 5555 707 283 5900 www panamax com...

Отзывы: