FEATURE DETAILS

6

Ground OK: 

Green LED.  When this light is ON, it indicates that the wall outlet is properly wired.  When the light is OFF,

it indicates that the wall outlet has a reversed line and neutral wire, or that there is no ground present. 

Line Fault: 

Red LED. When this light is ON, it is indicating that the wall outlet has a reversed line and neutral wire, or

there is no ground present.  This light will remain OFF if the wall outlet is properly wired. 

Unsafe Voltage: 

Red LED.  Under normal voltage conditions, this light stays OFF.  When this light is FLASHING slow-

ly (once per second), it indicates an undervoltage (<95 VAC) or overvoltage (>134 VAC) condition.  When the light is flash-
ing quickly (4 times per second), it indicates a 10 second recovery period from an under/overvoltage condition.  This light
will flash quickly when the MAX

®

5410 is first plugged into the wall outlet.

Meter Light Control 

Controls the brightness level, or turns the lighting off altogether.

Voltmeter

The analog Voltmeter is backlit to provide the ability to view the reading in a dark room.  LEDs (light emitting diodes) are
used as the light source in order to provide durability and long life.  The “Meter Light” dimmer controls the brightness level,
or turns the lighting off altogether.

The Voltmeter monitors the incoming voltage from the wall receptacle and provides a visual representation of the available
power.  The voltmeter is ALWAYS-ON and indicates the incoming line voltage even during an unsafe voltage condition.
Readings above 150VAC  will not be accurate due to the meter’s damping characteristics.

Convenience Outlet

A single outlet on the front panel of the MAX

®

5410 provides an easy to reach power source for electronic equipment typi-

cally used on a part time basis.  Such equipment includes anything from video game systems to camcorders. 

The convenience outlet not only provides superior surge suppression, but also taps into Filter Circuits to provide clean power
for your sensitive electronic equipment.  This outlet is an Always-On outlet and will continually supply a steady source of
power for your connected equipment.  

It is important to remember that power will be disconnected only in the event

of an unsafe voltage condition.

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

(Diagnostic Lights Continued)

Содержание MAX 5410 Pro

Страница 1: ...MAX 5410 Pro Series Owner s Manual 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Страница 2: ...ed noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for each piece of equipment in your entertainment...

Страница 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Страница 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Страница 5: ...3 CONNECTION DIAGRAMS Basic Signal Line Connections Typical AC Power RS232 and 12V Trigger Connections USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 STEP 1 STEP 2...

Страница 6: ...witch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satellite Coax Jacks Two pairs of gold plated F Connectors optimized for Satellite TV signal line protec...

Страница 7: ...n button is pressed quickly 2 sec SWITCHED and HIGH CURRENT outlets turn off for 10 seconds then turn back on in a sequence per delay settings The purpose is to cycle power to equipment that locks up...

Страница 8: ...dark room LEDs light emitting diodes are used as the light source in order to provide durability and long life The Meter Light dimmer controls the brightness level or turns the lighting off altogethe...

Страница 9: ...is comprehensive network of filters while banks 1 and 3 benefit from additional Balanced L filters Outlet Banks 1 and 2 contains four switched outlets that will turn your connected equipment ON or OFF...

Страница 10: ...ignal will initiate the startup or shutdown sequence of the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may als...

Страница 11: ...cy range of 950Mhz to 2 2Ghz The clamping level of the MAX 5410 s satellite protection circuitry is 27 volts just 3 volts above the maximum operating voltage The circuitry is shielded to prevent inter...

Страница 12: ...e following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage c...

Страница 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Страница 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Страница 15: ...t the status of the outlet banks PS responds with a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switch...

Страница 16: ...INS5410 REV A USA Canada 800 472 5555 707 283 5900 www panamax com...

Отзывы: