FEATURE DETAILS

Protect or Disconnect™ AC Surge Protection

When the MAX

®

5410 is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels

of surge current are diverted away from the connected equipment.

• When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the MAX

®

5410 limits

its voltage output to less than 330V peak, UL’s  lowest rating.  The MAX

®

5410 will withstand, without dam-

age, multiple 12,000A surges, far exceeding the UL maximum requirement of only  3,000 Ampere surges.

• If the magnitude of the surge is greater than the capacity of the surge protection components, the MAX

®

5410’s  Protect or Disconnect™ Circuitry will 

disconnect

your equipment in order to protect it.  The MAX

®

5410 will need to be repaired or replaced by Panamax if this occurs. (See Product Warranty).

SurgeGate Plus™ Protection

The MAX

®

5410 constantly monitors the AC line voltage for unsafe voltage conditions such as prolonged overvoltages and

undervoltages (brownouts).  These unsafe conditions pose a very dangerous threat to all electronic equipment within  the
home.  If the MAX

®

5410 senses an unsafe power condition, it will automatically 

disconnect 

your equipment from the

power to protect equipment from damage.  Once the voltage returns to a safe level, the MAX

®

5410 will automatically

reconnect 

the power.

If the line voltage exceeds the overvoltage threshold (134VAC) or falls below the undervoltage threshold (95VAC), the 
MAX

®

5410 will perform the following tasks until line voltage returns to a safe level:

1. Disconnects power to all connected equipment.
2. Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition.

The MAX

®

5410 requires line voltage to return to within the safe operating range for 10 seconds before returning to normal

operating mode.  This is referred to as “Over/Undervoltage Recovery”.  The safe operating range is considered 5V above the
under-voltage threshold (~100V) and 5V below the overvoltage threshold (~129V).  Once this safe operating range is
reached,  the MAX

®

5410 will perform the following functions:

1. 

Unsafe Voltage LED

will blink 4 times per second for Over/Undervoltage Recovery.

2. Power is restored to all connected equipment after the 10-second delay.  The normal start-up sequence 

as determined by the “High-Current Outlets Turn-On Switch” and “Outlet Bank 2 Turn-Off Switch” will 

be followed. 

The MAX

®

5410 provides protection against common problems on the AC power line.  This includes spikes/surges and

sustained overvoltages or undervoltages.  Panamax’s exclusive Protect or Disconnect™ circuitry is designed to protect
against spikes/surges while the SurgeGate Plus™ circuitry is for sustained over/under voltage protection.

1.

Voltage reaches an unsafe high

level and the SurgeGate Plus™ 

disconnects.

2.

Voltage reaches a safe level and

SurgeGate Plus™ automatically 

reconnects.

3.

Voltage reaches an unsafe low level

and SurgeGate Plus™ 

disconnects.

4.

Voltage reaches a safe level and

SurgeGate Plus™ automatically 

reconnects.

1.

Voltage reaches an unsafe level.

2.

If surge is greater than MAX

®

5410

capacity, it 

disconnects.

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

Содержание MAX 5410 Pro

Страница 1: ...MAX 5410 Pro Series Owner s Manual 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Страница 2: ...ed noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for each piece of equipment in your entertainment...

Страница 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Страница 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Страница 5: ...3 CONNECTION DIAGRAMS Basic Signal Line Connections Typical AC Power RS232 and 12V Trigger Connections USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 STEP 1 STEP 2...

Страница 6: ...witch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satellite Coax Jacks Two pairs of gold plated F Connectors optimized for Satellite TV signal line protec...

Страница 7: ...n button is pressed quickly 2 sec SWITCHED and HIGH CURRENT outlets turn off for 10 seconds then turn back on in a sequence per delay settings The purpose is to cycle power to equipment that locks up...

Страница 8: ...dark room LEDs light emitting diodes are used as the light source in order to provide durability and long life The Meter Light dimmer controls the brightness level or turns the lighting off altogethe...

Страница 9: ...is comprehensive network of filters while banks 1 and 3 benefit from additional Balanced L filters Outlet Banks 1 and 2 contains four switched outlets that will turn your connected equipment ON or OFF...

Страница 10: ...ignal will initiate the startup or shutdown sequence of the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may als...

Страница 11: ...cy range of 950Mhz to 2 2Ghz The clamping level of the MAX 5410 s satellite protection circuitry is 27 volts just 3 volts above the maximum operating voltage The circuitry is shielded to prevent inter...

Страница 12: ...e following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage c...

Страница 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Страница 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Страница 15: ...t the status of the outlet banks PS responds with a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switch...

Страница 16: ...INS5410 REV A USA Canada 800 472 5555 707 283 5900 www panamax com...

Отзывы: