Palsonic AOS Скачать руководство пользователя страница 2

CONTENTS

Preparation before use

Before using the air conditioner, be sure to check and preset the following.

Remote Controller presetting
The remote controller is 

NOT

 presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer.

Each time after the remote controller replaces batteries or is energised, the arrowhead will flashes on the
Front of "Heat" or "Cool" on LCD of the remote controller.
User can preset the remote controller type depending on the air conditioner type you have purchased as
follows:
Press any button when the arrowhead flashes and pointing to "Heat, then Heat Pump is set
Press any button when the arrowhead flashes and pointing to "Cool", then Cooling Only is set.
If you don't press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.

Note:
if the air conditioner you purchased is a Cooling only one, but you preset the remote controller as Heat Pump,
it doesn't bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the 
emote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.

Auto-restart Presetting:
The appliance is preset as no auto-restart function by manufacture. If Auto-restart function is needed, follow the
step below to activate this function:
1) Make sure the Air-con's power is off:
2) Press down and hold the Emergency button (ON/OFF )on the indoor unit then electrify.
3) Keep pressing the Emergency button for over 10 seconds until three short beeps are heard.
    The Auto-restart function is then activated. To cancel the Auto-restart function, repeat above procedure until four
    short beeps are heard.

Safety Precautions ....................................................................................................................

Identification of Parts .................................................................................................................

Remote Controller .....................................................................................................................

Operation Instructions ...............................................................................................................

Maintenance ..............................................................................................................................

Protection ..................................................................................................................................

Troubleshooting .........................................................................................................................

Installation Instructions ..............................................................................................................

1

2

4

6

8

9

10

11

Содержание AOS

Страница 1: ...be fore using your air conditioner After reading store it in a Safe place Please refer to the manual for questions on use or in the event that any irregularities occur This Air Conditioner should be...

Страница 2: ...air conditioner you purchased is a Cooling only one but you preset the remote controller as Heat Pump it doesn t bring any matter But if the air conditioner you purchased is a Heat Pump one and you pr...

Страница 3: ...e pull or press the power supply cord as this cold will be damaged and an electric shock or fire is probably caused by a broken power supply cord It is harmful to your health if the cool air reaches y...

Страница 4: ...standard model Consequently the shape may differ from that of the air conditioner you have selected Air intake Front Panel Emergency Panel Display Panel Air Outlet Drain Hose Air Intake Air Filter Re...

Страница 5: ...suitable for Q series Remarks When remote controller is out of work open the panel and you can see emergency button there see the above picture The emergency button for 50 70 90 series is at the top r...

Страница 6: ...lease subject to the substantiality When the batteries are inserted into the remote controller all the signals will display on the screen and keep 2 seconds then the COOLING and HEATING signals will f...

Страница 7: ...echargeable batteries Replace batteries with new ones of the same type when the display becomes dim Storage and Tips for Using the Remote Controller The remote controller may be stored mounted on a wa...

Страница 8: ...ith the button or the button There will be a delay when changing mode is made during the operation As there might not be air blown out If you don t like the content of FEEL mode operation change to HE...

Страница 9: ...can also set timer off at night to enjoy a good sleep Press UP and DOWN button to set time Time setting is 30 minutes Note After setting the timer check that TIMER INDICATOR lamp of the indoor unit l...

Страница 10: ...ront panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter It is necessary to clean the air filter after using it for about 100 hours Clean it as fol...

Страница 11: ...ing it for 5 years even if none of the above occurs If all operation has stopped press ON OFF button again to restart Timer should be set again if it has been cancelled Preheat At the beginning of HEA...

Страница 12: ...or heating air Does not run If the plug is not properly plugged in If batteries in the remote controller are exhausted If the protective device works to protect the appliance If the protector trip or...

Страница 13: ...the wall should be over 250mm Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased Installation must be performed in accordance wit...

Страница 14: ...elevision radio etc Keep as far as possible away from fluorescent lamps Do not put anything near the air inlet to obstruct it from air absorption Where there is strong enough to bear the weight and is...

Страница 15: ...ng Note The shape of your mounting plate may be different from the one above but the installation method is similar 2 Drill a Hole for Piping Decide the position of hole for piping according to the lo...

Страница 16: ...s Thermal Insulation Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape Piping Thermal Insulation a Place the drain hose under the piping b Insulation material us...

Страница 17: ...ir conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Confirm that the cable thickness is as specified in the power source specification See...

Страница 18: ...Install and Fix Outdoor Unit Fix with bolts and nuts tightly on a flat and strong floor If installed on the wall or roof make sure to fix the supporter well to prevent it from shaking due to serious v...

Страница 19: ...ct it in case of need If not possible connect appliance to a double pole switching device with contact separation of at least 3 mm placed in an accessible position even after installation Installation...

Страница 20: ...AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL 02 9313 7111 FAX 02 9313 7555 www palsonic com au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA 1300 657 888 1130010274 1 0...

Отзывы: