Protection 

For Tropical (T3) Climate condition models, the
temperature point is 52

0

C instead of 43%.

If the air conditioner runs in COOLING or DRY mode with
door or window opened for a long time when relative

humidity is above 80%, dew may drip down from the outlet

.

Install the air conditioner at a place that
can bear its weight in order to operate
more quietly.

Install the outdoor unit at a place where
the air discharged and the operation noise
would not annoy your neighbours.

Do not place any obstacles in front of the
air outlet of the outdoor unit lest it increases
the noise level 

Restarting the unit at once after operation
stops or changing mode during operation, you
need to wait  3 minutes.

Overheat of the power supply cord and plug
or even a burning smell.
Abnormal operating sound or vibration.
Water leakage from indoor unit.
Metal cabinet electrified.

Connect to power supply and turn on
the unit at once, it may start 20 seconds
later.

Stop the air conditioner if above occurs.
It is advisable to have a detail inspection after
using it for 5 years even if none of the above
occurs

If all operation has stopped, press ON/OFF
button again to restart.
Timer should be set again if it has been
cancelled.

Preheat

At the beginning of 

HEATING

 operation, the airflow from the indoor unit is discharged 2-5

minutes later.

Afferheat

After the finishing of 

HEATING

 operation, the airflow from the indoor unit is discharged 2-5

minutes.

Defrost

In 

HEATING

 operation the appliance will defrost (de-ice) automatically to raise efficiency.

This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.

After defrosting completes, it returns to 

HEATING

 mode automatically.

Note: Heating is NOT available for cooling only air conditioner models.

The protective device will work as follows.

After using for a long time, the air conditioner
should be inspected on the following items.

Inspection

Features of protector

Features of HEATING mode

Outdoor air temperature is over 24

0

C

Outdoor air temperature is below -7

0

C

Room temperature is over 27

0

C

Outdoor air temperature is over * 43

0

C

Room temperature is below 21

0

C

Room temperature is below 18

0

C

HEATING

COOLING

DRY

Operating condition

The protective device may trip and stop
the appliance in cases listed below.

Noise pollution

Содержание AOS

Страница 1: ...be fore using your air conditioner After reading store it in a Safe place Please refer to the manual for questions on use or in the event that any irregularities occur This Air Conditioner should be...

Страница 2: ...air conditioner you purchased is a Cooling only one but you preset the remote controller as Heat Pump it doesn t bring any matter But if the air conditioner you purchased is a Heat Pump one and you pr...

Страница 3: ...e pull or press the power supply cord as this cold will be damaged and an electric shock or fire is probably caused by a broken power supply cord It is harmful to your health if the cool air reaches y...

Страница 4: ...standard model Consequently the shape may differ from that of the air conditioner you have selected Air intake Front Panel Emergency Panel Display Panel Air Outlet Drain Hose Air Intake Air Filter Re...

Страница 5: ...suitable for Q series Remarks When remote controller is out of work open the panel and you can see emergency button there see the above picture The emergency button for 50 70 90 series is at the top r...

Страница 6: ...lease subject to the substantiality When the batteries are inserted into the remote controller all the signals will display on the screen and keep 2 seconds then the COOLING and HEATING signals will f...

Страница 7: ...echargeable batteries Replace batteries with new ones of the same type when the display becomes dim Storage and Tips for Using the Remote Controller The remote controller may be stored mounted on a wa...

Страница 8: ...ith the button or the button There will be a delay when changing mode is made during the operation As there might not be air blown out If you don t like the content of FEEL mode operation change to HE...

Страница 9: ...can also set timer off at night to enjoy a good sleep Press UP and DOWN button to set time Time setting is 30 minutes Note After setting the timer check that TIMER INDICATOR lamp of the indoor unit l...

Страница 10: ...ront panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter It is necessary to clean the air filter after using it for about 100 hours Clean it as fol...

Страница 11: ...ing it for 5 years even if none of the above occurs If all operation has stopped press ON OFF button again to restart Timer should be set again if it has been cancelled Preheat At the beginning of HEA...

Страница 12: ...or heating air Does not run If the plug is not properly plugged in If batteries in the remote controller are exhausted If the protective device works to protect the appliance If the protector trip or...

Страница 13: ...the wall should be over 250mm Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased Installation must be performed in accordance wit...

Страница 14: ...elevision radio etc Keep as far as possible away from fluorescent lamps Do not put anything near the air inlet to obstruct it from air absorption Where there is strong enough to bear the weight and is...

Страница 15: ...ng Note The shape of your mounting plate may be different from the one above but the installation method is similar 2 Drill a Hole for Piping Decide the position of hole for piping according to the lo...

Страница 16: ...s Thermal Insulation Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape Piping Thermal Insulation a Place the drain hose under the piping b Insulation material us...

Страница 17: ...ir conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Confirm that the cable thickness is as specified in the power source specification See...

Страница 18: ...Install and Fix Outdoor Unit Fix with bolts and nuts tightly on a flat and strong floor If installed on the wall or roof make sure to fix the supporter well to prevent it from shaking due to serious v...

Страница 19: ...ct it in case of need If not possible connect appliance to a double pole switching device with contact separation of at least 3 mm placed in an accessible position even after installation Installation...

Страница 20: ...AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL 02 9313 7111 FAX 02 9313 7555 www palsonic com au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA 1300 657 888 1130010274 1 0...

Отзывы: