This room heater must be installed in accordance with this advice to be covered by the Paloma warranty.  

 

This room heater is suitable for indoor installation only. 

 

This appliance must be installed in accordance with: 

o

 

Local Gas Fitting Regulations 

o

 

Municipal Building Codes 

o

 

Australian Standard for Gas Appliance Installations AS/NZS5601.1:-2010 

o

 

Any other relevant Statutory Regulation 

o

 

Manufacturer’s installation instructions 

 

This appliance must be serviced by a qualified person. 

 

This heater must be installed with a minimum clearance of 50mm from the rear and sides. These 
clearances must be maintained at all times. 

 

There must be a minimum clearance of 750mm from the hot air outlet. 

 

Do not install in a room with inadequate ventilation – refer to Australian Standard AS/NZS5601.1:-2010. 

 

Do not install on an uneven surface or a vibrating floor. 

 

Do not install directly on to carpet, timber floor, vinyl floor or cork floors. Heat emanating from these 
appliances may discolour the carpet or damage your floor. It is recommended that a mat or flat board be 
placed in front of this appliance extending at least 800mm in front of it. 

 

Do not install near a door or windy location or under shelves or in a confined space. E.g.: fireplace. 

 

Do not install in a bedroom, bathroom, combined living/sleeping areas, toilets or sauna. 

 

Do not install where flammable materials are likely to come into contact with the heater. 

 

Do not install where water may splash or near another heat source. 

 

Do not install in a caravan, mobile home or recreational vehicle. 

 

Do not connect to a Propane (LPG) gas cylinder 

indoors

 

This appliance is not designed to be built into walls or cupboards. 

 

If you move house check the gas type in the house where you are moving to. 

 

The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting.  

 

Do not place heater against wall or on a shelf. 

 

Always place heater on flat surface and away from strong draughts. 

 

It is recommended that a dedicated 240V 10Amp power point be used with this appliance. Do not use 
power boards or double adaptors to operate this appliance. Heater must not be located adjacent to a 
power socket – outlet. 

 

Turn the heater off after use. Do not unplug the heater while it is in operation or while the fans are still 
cycling. 

 

Do not move the heater while it is in operation. 

 

When the heater is operated for the first time or after long periods of non use a slight odour may be 
emitted, this is normal. However if odours persist switch off the heater and contact Rheem Service. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation 

Содержание PJC-S13F

Страница 1: ...ons b Municipal Building Codes c Australian Standard for Gas Appliance Installations AS NZS5601 1 2010 d Any other relevant Statutory Regulation e Manufacturer s installation instructions 3 This appli...

Страница 2: ...Caution 6 Installation 7 Regular Care Maintenance 8 Operating Instructions Start Up 9 Room Temp Adjustment 9 Turning Heater Off 9 Adjustment Hot Air Outlet 9 Economy Operation 10 Air Filter 10 Troubl...

Страница 3: ...tch off the heater and the filter light will flash Anti tilt Safety Switch automatically shuts off gas flow if the heater is knocked or bumped Oxygen Depletion Safety System automatically shuts off ga...

Страница 4: ...fied on the rating plate matches your gas supply WARNING Using a different type of gas may cause an explosive ignition resulting in injury damage to heater or malfunction of the oxygen depletion safet...

Страница 5: ...FY THIS APPLIANCE NOT INTENDED FOR FIREPLACE INSERT NOT TO BE CONNECTED TO AN LPG GAS CYLINDER LOCATED INDOORS PLEASE ENSURE THAT THE GAS SPECIFICIED ON THE RATING PLATE MATCHES YOUR GAS SUPPLY USING...

Страница 6: ...e that children do not play with this appliance Do not sit stand or lean on the heater Do not insert your fingers into the louvres or the air inlet of the heater Do not cut the electrical cord to exte...

Страница 7: ...y location or under shelves or in a confined space E g fireplace Do not install in a bedroom bathroom combined living sleeping areas toilets or sauna Do not install where flammable materials are likel...

Страница 8: ...g cloths benzene acid or alkaline detergents as this could discolour the paint and plastic components Outer Casing Always keep the heater clean Use a damp soft cloth to wipe Use mild soapy water if re...

Страница 9: ...can be raised or lowered by using the temperature selection buttons Press any temperature selection button to show the current room temperature The actual room temperature is shown by the flashing gr...

Страница 10: ...allowed to reduce by one degree up to maximum of two degrees for a period of 60 minutes This subtle reduction in temperature is not noticed by the user AIR FILTER If the filter light yellow comes on...

Страница 11: ...heater is switched off It stops after the temperature inside the heater has cooled No action required The heater creaks at the time of lighting or switching off The sound is caused by expansion and co...

Страница 12: ...er the tilt switch will cut off the supply of gas to the heater The tilt switch may also operate if the heater is jolted whilst in operation 4 OVERHEAT SWITCH When the fan stops rotating for any reaso...

Страница 13: ...ater is at Paloma Rheem s sole discretion 2 Where a failed component is replaced under this warranty the balance of the original warranty period will remain effective The replacement does not carry a...

Страница 14: ...12 If you require a call out and we find that the fault is not covered by Paloma warranty you are responsible for our standard call out charge If you wish to have the relevant components repaired or r...

Страница 15: ...purchase require proof of purchase and serial number from the rating label on the convection heater 2 Rheem will arrange for the convection heater to be tested and assessed on site 3 If Rheem determi...

Страница 16: ...wing 1 Please read these instructions carefully 2 Refer to trouble shooting guide page 11 and malfunction display chart page 11 3 Contact Rheem Service These Paloma models have been certified by the A...

Отзывы: